Influence of Connection Configuration on Stress Redistribution and Joint Core Damage in Grout-Filled Steel Tubular X Assemblies Under Compression
The compressive resistance of tubular X supports in building structures depends on the stress state in the joint core. This study combines laboratory compression tests and three-dimensional finite element analysis to investigate grout-filled steel tubular X assemblies with a directly intersecting joint (IJ) and a rib-p...