Data-Free Knowledge Distillation (DFKD) preserves privacy by transferring knowledge without real data access. However, existing generator-based DFKD methods suffer from over-reliance on teacher preferences and pattern collapse, exhibiting"generative shortcut learning"in the frequency domain: dependent on specific frequency components and frequency positions, resulting in inconsistent synthetic image quality and class diversity. In this paper, we propose a CSWL framework aimed at introducing insights from the frequency domain perspective to improve generator diversity and training stability to Close the phenomenon of Shortcut learning to Win in the Longer term. To address the issue of generative shortcut learning, we introduce frequency-domain augmentation at the feature level, encouraging the generator to attend to the full frequency spectrum and thereby suppress shortcut learning behavior. To tackle training instability, we propose a Cross-Stage Frequency Reconstruction (CSFR) auxiliary task, which implicitly constructs an Exponential Moving Average (EMA) mechanism to promote long-term optimization and stability. Extensive experiments, including downstream tasks and various image recognition datasets at multiple resolutions, validate the effectiveness of CSWL in improving both diversity and stability from the frequency view.
Kailin Lyu, Zherui Zhang, Jun-Hao Dong et al.· 0 citations
Deep learning has shown strong potential in medical image analysis, but most existing methods rely on large-scale annotations and a closed-world assumption that rarely holds in clinical practice. Although Generalized Category Discovery (GCD) has advanced rapidly on natural images, it remains underexplored in medical imaging. To address this issue, we propose MedXplore, a unified framework for reliable and unbiased medical GCD, optimizing from both perceptual and decision levels. Specifically, at the perceptual level, taking a frequency domain perspective, Frequency-SNR Adaptive Attention and Consistency (FAAC) performs learnable full-spectrum filtering and global-local energy contrast activation to not only highlight local abnormal signals relative to the global context, but also provide reliable semantic anchors for patch consistency learning. At the decision level, Adaptive Cosine-Angular Margin (ACAM) adjusts angular margins using semantic difficulty and feature confidence to balance intra-class compactness and inter-class separability. Together, the two modules improve lesion-sensitive representation learning and mitigate old-class bias. Experiments on multiple benchmarks show an average \textbf{8.5\%} gain in \textit{All} accuracy over the strongest competing methods. On Kvasir, MedXplore reduces false-old errors from 14.50\% to 0.80\%, demonstrating strong robustness under severe old-new ambiguity.