Integrated Turboshaft FADEC Architecture and the Effect of Governor Implementation on Protection-Layer Loading
Comparative studies of turboshaft fuel controllers commonly report performance advantages without holding the loop bandwidth or anti-windup implementation constant across the compared configurations. This paper asks what survives such a comparison. An integrated FADEC architecture for a GE T700-class turboshaft is deve...