Skip to content

Author

Murodbek Akhrorov

1 paper indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Review Open access Jul 2026

Uncertainty-Aware Prediction Across Endoscopic Domains: Laryngeal Narrow-Band and Gastrointestinal Imaging

Background: Deep-learning systems for endoscopic image classification are commonly evaluated with random data splits, which may overestimate performance under acquisition shift; uncertainty-aware selective prediction may improve reliability by allowing a model to abstain on uncertain cases. Methods: We evaluated binary abnormality detection in two endoscopic imaging domains: laryngeal contact-endoscopy narrow-band imaging (CE-NBI; 210 patients, patient-level) and gastrointestinal endoscopy (HyperKvasir; 6746 images, image-level, predominantly white-light). ImageNet-pretrained ResNet-50 deep ensembles were assessed under a resolution-defined acquisition-shift stress test; for the gastrointestinal data, a random stratified split was additionally used as an in-distribution reference. We evaluated discrimination, calibration, decision-curve analysis, and entropy-based selective prediction. Results: In the gastrointestinal dataset, random-split evaluation produced high performance (AUROC 0.994, 95% CI 0.990–0.996; AUPRC 0.991). Under resolution shift on the same data, performance fell to AUROC 0.723 (95% CI 0.710–0.736; AUPRC 0.690; sensitivity 0.417; specificity 0.874); the two intervals do not overlap. Selective prediction improved reliability among retained cases: under resolution shift, accuracy rose from 0.683 at full coverage to 0.852 (95% CI 0.835–0.871) at 25% coverage (balanced accuracy 0.646 → 0.798). Predictive entropy was significantly higher for incorrect than for correct predictions in both regimes (Mann–Whitney p = 7.1 × 10−77 with rank-biserial |r| = 0.30 under shift). In the laryngeal cohort, no statistically significant differences were detected among four architectures (ROC-AUC 0.844–0.901; all pairwise DeLong p > 0.05). Conclusions: Random-split evaluation substantially overestimated performance relative to a resolution-defined acquisition-shift stress test, and entropy-based selective prediction improved reliability by identifying a high-confidence subset for automated prediction while deferring the remainder to human review. Target-domain recalibration substantially restores calibration under shift (ECE 0.172 → 0.036 with temperature scaling; → 0.017 with isotonic regression) but does not recover discrimination; selective prediction is complementary, mitigating residual confident-wrong predictions. An encoder-transfer experiment showed asymmetric cross-domain utility; features learned on the larger gastrointestinal cohort transferred to the laryngeal cohort (AUROC 0.80 vs. in-domain 0.89), whereas the reverse direction did not transfer (0.53 vs. 0.72). Prospective multi-center validation remains required before clinical deployment. All code, fold definitions, random seeds, and a reproducible protocol are publicly released.

Behnam Kiani Kalejahi, S. Khan, Murodbek Akhrorov et al. · 0 citations