A New Algorithm for Management of Corneal Astigmatism Using Toric Intraocular Lenses
Background and Objectives: To assess refractive and visual outcomes following phacoemulsification using a novel algorithm for toric intraocular lens (IOL) surgery. Setting: Private practice, Spain. Design: Prospective observational study. Materials and Methods: The algorithm was designed to control the topographic posi...