Experimental Investigation and Restoring Force Model of Steel Archaizing Building Joints with Viscous Dampers
To enhance the seismic performance of steel archaizing buildings without altering their traditional architectural appearance, viscous dampers were installed in the Que-ti bracket regions of beam–column joints. Dynamic cyclic loading tests were conducted on four viscous damper-equipped joint specimens with single-beam a...