Axial Compression Behavior of Pre‐Damaged SRC Short Columns Subjected to Chloride Salt Corrosion
To investigate the axial compression performance of pre‐damaged steel‐reinforced concrete (SRC) columns under chloride corrosion, this study first analyzed the material degradation mechanism of steel and concrete. Pre‐damage tests were then conducted on 10 SRC short column specimens to examine the effects of key design...