Aug 2026· Physics in Medicine and Biology· Vol 71· 0 citations· 20 references
MedicinePhysics
TL;DR
A compact representation of PSF using sinusoidal implicit representation networks (SIRENs) that enables limitless sampling while preserving dosimetric accuracy is introduced and evaluates.
Abstract
Objective. Phase space files (PSFs) are commonly used to restart Monte Carlo simulations from pre-calculated conditions, but are large and unwieldy. This study introduces and evaluates a compact representation of PSF using sinusoidal implicit representation networks (SIRENs) that enables limitless sampling while preserving dosimetric accuracy. Approach. Three models were developed to account for the different types of particles found in photon phase spaces: primary photons, secondary photons, electrons. For each particle type, a sequence of 2 or 3 SIRENs were trained to learn the implicit neural representation of the probabilistic distribution of particle position, direction and energy. Once trained, PSFs of any desired size can be generated by sampling the probability density functions implicitly represented by the model. We applied this approach to vendor-provided 6 and 10 MV photon phase spaces. Model accuracy was validated by using the network-sampled particles as input to an EGSnrc Monte Carlo dose calculation in a water phantom. Scalability is further investigated by training the model on 20% of the original PSF particles. Main results. SIREN reproduced marginal probability distributions and depth dose curves with excellent agreement. Lateral profiles showed small discrepancies in penumbra shoulders. 2%/0 mm Gamma pass rates were 97.2%, 98.1%, 96.9% and 99.2% for 6X, 6FFF, 10X and 10FFF, respectively. Mean voxel-wise dose difference was 0.44% (6X), 0.36% (6FFF), 0.51% (10X) and 0.25% (10FFF) versus vendor PSFs. Training on 20% of particles slightly reduced the 6X gamma pass rate from 97.2% to 96.3% while maintaining dose profile agreement. The approach achieved ∼30 000-fold compression (1.6 MB vs 50 GB) with an average sampling time of ∼0.8 s per 106 particles on an NVIDIA RTX 6000 Ada. Significance. The SIREN-based approach allows for a compact representation of Monte Carlo PSF with high dosimetric fidelity. It remains robust with reduced training data and would enable on-the-fly sampling of particles without recycling.
Objective. The BioDoseActor, a new tool implemented in the GATE Monte Carlo platform, aims to calculate the biological dose and its associated uncertainty for hadrontherapy treatment plans. This tool is designed to facilitate the validation of biophysical models and optimize clinical treatment planning by providing acc...
Alexis Pereda, Thomas Berger, M. Beuve et al.· Physics in Medicine and Biol...· 1 citation
A channel-decoupled multi-path state space model (MPC-SSM) is designed that flattens the 3D SM into multiple complementary spatial sequences, and uses different traversal paths to capture anisotropy and long-range spatial dependencies.
Zhao-Ji Miao, Li-Wen Zhang, Zi-Wei Chen et al.· Physics in Medicine and Biol...· 0 citations
Purpose: To develop and describe the architecture of a physical module for a Dose-Anatomical Planning System (DAPS) for ion beam therapy based on the GEANT4 platform, and to optimize its computational efficiency for clinical application under limited computing resources.
Material and methods: Simulation of the interac...
M. A. Makarova, O. Yushchenko· Meditsinskaya Fizika· 0 citations