Aug 2026· Artif. Intell. Medicine· Vol 181, pp.
103511
· 0 citations· 31 references
Computer ScienceMedicine
TL;DR
The proposed DiffCAS surpasses state-of-the-art image generative methods, achieving superior reconstruction accuracy, structural consistency, and diagnostic reliability and highlights the proposed DiffCAS as a clinically promising, inference-time CT-free solution for attenuation correction in cardiac SPECT imaging.
Abstract
Attenuation artifacts remain a critical challenge in cardiac Myocardial Perfusion Imaging (MPI) using Single-Photon Emission Computed Tomography (SPECT), often degrading diagnostic accuracy and clinical interpretability. While hybrid SPECT and Computed Tomography (CT) systems mitigate these artifacts using CT-derived attenuation maps, their high cost, radiation exposure, and limited accessibility restrict widespread clinical use. To address these challenges, we propose DiffCAS, an inference-time CT-free diffusion model for physics-aware multi-slice attenuation correction in cardiac SPECT. DiffCAS integrates a Brownian Bridge diffusion process with physics-guided supervision, enabling the generation of attenuation-corrected (AC) images directly from non-attenuation-corrected (NAC) inputs. Specifically, a physics-aware reconstruction module predicts voxel-wise attenuation coefficients and path lengths, then combines them via the Beer-Lambert law into an attenuation correction factor applied at each diffusion step, keeping the AC images physically consistent. The model introduces two key innovations that jointly enhance structural understanding and physics consistency. The first is multi-slice contextual learning, which captures cross-slice anatomical dependencies and improves spatial coherence in reconstructed images. The second is the 3D Computed Tomography Vision Transformer that models long-range volumetric structures and provides physics-consistent attenuation priors to guide the diffusion process. To enable CT-free attenuation correction, DiffCAS introduces the teacher-student distillation framework that transfers physics-informed knowledge from CT-conditioned training to a student network that requires no CT input at inference time, ensuring stability and interpretability. Evaluations on the CardiAC dataset, which comprises 424 patient studies with paired NAC and AC, and CT-based attenuation maps, demonstrate the strong performance of DiffCAS, evaluated using global pixel-level metrics and myocardium-specific clinical metrics. The proposed method surpasses state-of-the-art image generative methods, achieving superior reconstruction accuracy, structural consistency, and diagnostic reliability. These results highlight the proposed DiffCAS as a clinically promising, inference-time CT-free solution for attenuation correction in cardiac SPECT imaging.
BACKGROUND AND OBJECTIVE
Non-contrast coronary magnetic resonance angiography (NC-CMRA) suffers from inherent low spatial resolution, whereas existing deep learning-based super-resolution methods offer no reliability assessment, which hinders their clinical adoption.
METHODS
To bridge this gap, we develop a task-tail...
Fang-Yi Xing, Ning Cao, Xiu-Han Li et al.· Computer Methods and Program...· 0 citations
Multi-phase contrast-enhanced CT (CECT) is widely employed to capture the dynamic enhancement patterns and temporal evolution of organs and lesions. However, acquiring multiple phases increases radiation exposure and is inevitably accompanied by inter-phase misalignment and inconsistencies due to patient motion and the...
Xing Li, Miao-Miao Wang, Bao-Ping Zhang et al.· IEEE Transactions on Image P...· 0 citations
A single platform can integrate MR-Linac DWI post-processing with traceable, expert-evaluated clinical interpretation, while highlighting the safeguards needed to verify LLM-generated reasoning in radiation oncology.
Yunxiang Li, Yan Dai, Yen-Peng Liao et al.· 0 citations
Simulation-embedded reconstruction enabled integrated physical modeling within iterative reconstruction and improved the agreement with ideal reference images under controlled phantom-based conditions and supported the technical feasibility and basic validity of acquisition-consistent Monte Carlo-embedded reconstructio...
S. Shirakawa, Sayaka Fujita, H. Azuma et al.· Physica medica (Testo stampa...· 0 citations
SinoDiff is a novel self-supervised, physics-consistent diffusion framework for the recovery of PET sinograms across multiple predefined dose levels, and achieves competitive performance against supervised and self-supervised baselines across multiple dose levels.
Ghulam Nabi Ahmad Hassan Yar, Himashi Peiris, S. Jamadar et al.· 0 citations
As part of the Big Cross-Modal Attenuation Correction Challenge (BIC-MAC), we aimed to synthesise pseudo-CT images for PET/MR attenuation correction from whole-body non-attenuation-corrected PET (NAC-PET), Dixon MRI, and a two-dimensional topogram image. We developed a residual 3D U-Net in which a dedicated 2D topogram...
Joris Wuts, J. Ceranka, Vicky De Ridder et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.