Aug 2026· Translational Vision Science & Technology· Vol 15, pp. 3· 0 citations· 41 references
Medicine
TL;DR
Sensitivity measurements from AO microperimetry were repeatable within and across sessions, and will guide future longitudinal studies of disease progression in detecting sensitivity changes using AO microperimetry.
Abstract
Purpose To assess the within and between-session repeatability of foveal sensitivity measurements using adaptive optics (AO) microperimetry. Methods Five normal-sighted participants underwent AO microperimetry testing (550-nm circular stimulus) at the preferred retinal locus across two sessions (2 months ± 2 weeks). Two psychophysical paradigms were used: quick estimation of threshold (QUEST) and method of constant stimuli (MOCS). Each paradigm employed both 1.05-arcmin2 and 30.4-arcmin2 stimulus sizes; stimuli were not stabilized in real time. Trial-by-trial responses were fit with a logistic psychometric function to obtain thresholds at a criterion of 78% seen. Thresholds were converted to sensitivity. Statistical comparisons were performed using paired-sample t-tests. Results Sensitivities measured from QUEST and MOCS procedures were not significantly different (QUEST: 1.05 arcmin2, P = 0.36 for session 1 and P = 0.41 for session 2; MOCS: 30.4 arcmin2, P = 0.14 for session 1 and P = 0.12 for session 2). Data were thus combined across paradigms for tests of repeatability. Sensitivities for data split into two groups within session 1 and separately within session 2 were not significantly different (QUEST: 1.05 arcmin2, P = 0.34 for session 1 and P = 0.51 for session 2; MOCS: 30.4 arcmin2, P = 0.31 for session 1 and P = 0.27 for session 2). Overall, sensitivities across the two sessions were not significantly different (QUEST: 1.05 arcmin2, P = 0.06; MOCS: 30.4 arcmin2, P = 0.81). The coefficients of repeatability across sessions were 1.5 decibels (dB) and 0.4 dB for 1.05 arcmin2 and 30.4 arcmin2, respectively. Conclusions Sensitivity measurements from AO microperimetry were repeatable within and across sessions. Translational Relevance Results of the present study will guide future longitudinal studies of disease progression in detecting sensitivity changes using AO microperimetry.
PURPOSE
To compare contrast sensitivity function (CSF) measurements obtained with either Gabor gratings or Sloan letters using the same LCD-based device, to evaluate the reliability of letter-based CSF testing and to establish normative values in a young healthy population.
METHODS
A new computerised chart for psycho...
Assunta Di Vizio, Riccardo Rolandi, A. Duse et al.· Ophthalmic & physiological o...· 0 citations
This study evaluated the repeatability, test duration, and relationships between AIM and FInD measures of near visual acuity, contrast sensitivity function (CSF), and form and motion coherence using tablet-based vision tests, supporting their potential for both research and clinical applications.
J. Green, Jan Skerswetat, Peter J. Bex et al.· Scientific Reports· 0 citations
Clinical relevance: Vernier acuity (VA) is a common clinical metric used to evaluate cortical visual processing and macular health that is relatively independent of typical optical limitations (such as blurring). Background: Past studies have shown that vernier thresholds do not tend to vary according to blur, intensit...
Yaw Buabeng, Billy R. Hammond· Vision· 0 citations
Bloch's Law states that up to a critical duration, typically between 30 and 100 ms, the detection of a flash depends on its total strength (the product of luminance and duration). This study investigated whether this principle of temporal summation extends to shape recognition, assessed via optotype-based visual ac...
Constantin C. Ketz, M. Bach, Sven P. Heinrich· Frontiers in Neuroscience· 0 citations
To investigate the practicability, accuracy, and consistency of the computerized optokinetic nystagmus (OKN) analyzer for visual acuity (VA) measurement. Cross-sectional consistency evaluation study. A total of 219 subjects (13.48 ± 12.89 years, 115 males, 104 females) underwent bilateral VA testing using a computerize...
Mei-Xia Jiang, Yun-Yun Sun, Jie Hong et al.· BMC Ophthalmology· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.