Comparative Analysis of Artificial Neural Network and Adaptive Neuro-Fuzzy Inference System Techniques for Fault Detection and Mitigation on the Nigerian 330 kV Transmission Network
Sep 2026· Iconic research and engineering journals· Vol 10, pp. 1227-1234· 0 citations· 18 references
TL;DR
A comparative simulation study of Artificial Neural Network and Adaptive Neuro-Fuzzy Inference System-derived intelligent protection techniques, benchmarked against Deep Learning and Genetic-Algorithm optimized variants, for fault detection, classification and mitigation on the 330 kV Onitsha – Enugu transmission corridor in Nigeria confirms that ANN-and ANFIS-derived architectures markedly outperform conventional threshold-based protection and reveals an accuracy – interpretability trade-off that motivates hybrid intelligent-relay deployment.
Abstract
- Transmission-line protection in modern power networks faces growing challenges from high-impedance faults, current-transformer saturation and power swings that degrade the performance of settings-based conventional distance relays. This paper reports a comparative simulation study of Artificial Neural Network (ANN) and Adaptive Neuro-Fuzzy Inference System (ANFIS)-derived intelligent protection techniques, benchmarked against Deep Learning (DL) and Genetic-Algorithm (GA) optimized variants, for fault detection, classification and mitigation on the 330 kV Onitsha – Enugu transmission corridor in Nigeria. A distributed-parameter, twenty-section π -model of the 250 km line, coupled with a ±150 MVAr Static Synchronous Compensator (STATCOM) under fuzzy-logic control, was developed in MATLAB/Simulink. Line-to-ground, line-to-line, double line-to-ground and three-phase faults were simulated at varying fault resistances, inception angles and locations to build a training and test dataset. A Multi-Layer Feed-Forward ANN trained with the Levenberg – Marquardt algorithm achieved 96.0% fault-classification accuracy with a fault-location error below 2.0%, while GA optimization raised classification accuracy to 97.2%. The fuzzy-logic-controlled STATCOM reduced voltage-recovery time from 0.25 s to 0.1 s (a 60% improvement) and limited the peak fault-current surge by 74%. The results confirm that ANN-and ANFIS-derived architectures markedly outperform conventional threshold-based protection and reveal an accuracy – interpretability trade-off that motivates hybrid intelligent-relay deployment.
The results indicate that phase-angle information provides supplementary and class dependent discriminative value, but does not consistently improve all fault classes, whereas conventional voltage and current measurements alone represent a simpler and more stable alternative, whereas phase-angle measurements may be inc...
Zeynep Bala Duranay, İsmail Anıl Avcı, Mohammed Bushra Mohammed et al.· Symmetry· 0 citations
Reliable fault detection and classification are essential for improving the security and operational stability of transmission networks. However, existing techniques often depend on effective feature extraction and may experience reduced performance under varying fault conditions. This study presents an intelligent fau...
Iniobong Essien, I. Abasi-obot, E. E. Ambrose et al.· Journal of Engineering Resea...· 0 citations
The increasing operational complexity and fault vulnerability of Nigeria’s electrical distribution
networks demand intelligent systems capable of rapid fault detection, accurate localization, and
efficient isolation. This study develops an intelligent fault detection and location framework for
the Ayepe 34-bus Niger...
G. Ajenikoko· INTERNATIONAL JOURNAL OF APP...· 0 citations
Fault location in a power system is a sensitive task because of the grid’s complex environment. Traditional fault-location methods that rely only on impedance estimates or traveling waves are less accurate than before because modern transmission networks are more complex due to the integration of wind resources, power...
Shazia Kanwal, S. Jiriwibhakorn· Applied Sciences· 0 citations
Modern power transmission systems increasingly operate under stressed conditions characterised by load growth, reduced operating margins, ageing infrastructure, and extensive integration of converter-interfaced generation. These conditions strengthen the coupling between transient rotor-angle stability and voltage secu...
Itoro E. Udosen, N. Okpura, K. Udofia et al.· Journal of Engineering Resea...· 0 citations
Early and reliable diagnosis of inter-turn short-circuit (ITSC) faults is critical to maintaining the reliability, availability, and safe operation of doubly fed induction generators (DFIGs) used in wind energy conversion systems (WECSs). Incipient winding faults are particularly challenging to identify because their e...
M. Abid, S. Laribi, M'hamed Larbi et al.· Algorithms· 0 citations