Jul 2026· Fractal and Fractional· Vol 10, pp. 505· 0 citations· 29 references
Abstract
Grid-forming converters are essential for low-inertia power systems. However, their semiconductor current and junction-temperature limits make them vulnerable to protection-triggered blocking and thermal overstress during severe voltage sags. Existing control methods still struggle to suppress fault-instant current surges and the associated transient thermal stress induced by rapid overcurrent, which restricts the continuous operation of grid-forming converters during fault ride-through. This paper proposes a two-stage coordinated electro-thermal control strategy centered on fractional-order reactive power regulation. First, a fractional-order operator is embedded into the reactive-power loop of the virtual synchronous generator to smooth the transient response of the internal electromotive force and directly suppress the amplitude of fault-induced inrush current. By introducing a continuously tunable order, the proposed controller enhances transient damping, mitigates the waterbed effect trade-off associated with integer-order control, and reduces the initial junction-temperature shock at the fault instant. A constraint-based feasible-region identification procedure is then developed, in which a full-range parameter sweep is performed to screen fractional orders under stability, current, and thermal constraints. Second, generalized discontinuous pulse-width modulation and switching-frequency reduction are jointly applied to mitigate post-transient thermal accumulation. Electro-thermal co-simulation results indicate that, under the specified voltage-sag condition, the proposed strategy reduces transient overcurrent and thermal stress and improves the simulated fault-ride-through performance of grid-forming converters without additional hardware thermal margins.
To address the issues of excessive fault current, insufficient voltage support, and frequency oscillations in grid-forming converters during power grid short-circuit faults, this paper establishes a fault ride-through test model based on the principle of impedance voltage division and analyzes the fault transient chara...
Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault cu...
Hao-Yu Wang, Chi Zhang, Mafu Zhang et al.· 0 citations
: The deployment of grid-forming converters (GFMC) in weak-grid renewable energy stations can provide voltage support for grid-following converters (GFLC). However, the coupling between the two types of converters may cause the voltage-support capability of the GFMC to be constrained by its overcurrent capacity during...
Yuxuan Chen, Ying-Qi Yi, Meng-Yan Ni et al.· Energy Engineering· 0 citations
To address reactive power competition, high-frequency electromagnetic oscillations, and fault-energy propagation caused by active power backflow in doubly fed induction generators (DFIGs) under cascading faults, a master–slave coordinated fault ride-through strategy is proposed. First, a central-controller-led architec...
Tie-Zhu Chen, Yu-Xin Hu, Yu-Tong Li et al.· Engineering Research Express· 0 citations
With the large-scale integration of high-voltage direct-current (HVDC) transmission systems, the receiving-end AC grid exhibits weak voltage-support capability. Consequently, grid-forming (GFM) battery energy storage converters are required to satisfy both current-limiting and voltage-support requirements during fault...
Pu Liu, Zhao-Fan Wang, Yong-Peng Shen et al.· Electronics· 0 citations