Skip to content

Physics-Guided Flow Matching for CT Image Reconstruction

Aug 2026 · 1 citation · 27 references
Computer Science

TL;DR

Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps.

Abstract

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

View source

Similar papers

Preprint Aug 2026

Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors

This work introduces an unsupervised, optimization-based reconstruction framework that employs a flow-matching generative model as a learned manifold prior, yielding a differentiable generator of anatomically plausible images.

Heng-Jia Ran, Jie Luo, Yu-Tao Zhu et al. · 0 citations
Preprint Aug 2026

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

HiGDiff is proposed, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail in three distinct CT benchmark datasets.

Yuezhe Yang, Liang Cheng · 0 citations
Preprint Aug 2026

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

The proposed CM-RED method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction.

Merve Gülle, Junno Yun, Y. Alçalar et al. · 0 citations
Preprint Sep 2026

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have sho...

Jia-Le Shen, Guo-Lin Wang, Chen-Hao Wang et al. · 0 citations
Sep 2026

Non-Contrast-Informed Low-Dose Multi-Phase Contrast-Enhanced CT Reconstruction via Local Optimal Transport

Multi-phase contrast-enhanced CT (CECT) is widely employed to capture the dynamic enhancement patterns and temporal evolution of organs and lesions. However, acquiring multiple phases increases radiation exposure and is inevitably accompanied by inter-phase misalignment and inconsistencies due to patient motion and the...

Xing Li, Miao-Miao Wang, Bao-Ping Zhang et al. · 0 citations
Preprint Aug 2026

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

This work investigates whether a single diffusion model trained across several imaging domains can instead serve as a prior for many CT problems simultaneously, and proposes a frozen model that out-performs analytic reconstructions in all three cases.

Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman et al. · 0 citations