2025· 150th anniversary of the Metre Convention — From Units to the Universe· 0 citations
Abstract
Poly- and perfluoro alkyl substances (PFAS) are of increasing concern due to their wide spread occurrence in the environment, their bio-accumulative properties, slow biodegradation, and public health concerns. Making effective decisions regarding exposure limits and acceptable environmental levels demands high quality and reliable results. Accuracy based proficiency testing (PT) programs using reference values with metrological traceability are a valuable tool to demonstrate that analytical laboratories can deliver results to the required standard.
National Measurement Institute Australia (NMIA) conducted a PT program for PFAS (AQA 19-11) using a reference value for perfluorooctanoic acid (PFOA) in drinking water to assess the performance of participants. The reference value was determined by a primary method (Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry) underpinned by a Calibration and Measurement Capability (CMC) in the Key Comparison Database (KCDB) obtained after successful participation in a Consultive Committee for Amount of Substance (CCQM) Key Comparison. Reference values for other PFAS analytes are challenged by the lack of availability of calibrators listed in the KCDB and accepted under the International Committee for Weights and Measures Mutual Recognition Agreement (CIPM MRA).
To ensure accuracy of reference value it was important to address the challenges of internal standard equilibration, analyte behaviour during extraction, chromatographic interferences, and matrix effects. The method employed required 48 hours equilibration time for the 13C labelled internal standard, solid phase extraction, and two complimentary chromatographic conditions to demonstrate the absence of matrix interferences and effects. The SI traceable calibrator used was sourced from the National Metrology Institute of Japan (CRM 4056-a). The measurement uncertainty was estimated in accordance with JCGM 100:2008, with component contributions from method precision, gravimetric bias, calibration solution uncertainty, sample density, and potential matrix interferences. The largest contributor to uncertainty was the component associated with the calibration solution, contributing 57% of the total variance. In contrast, analytical precision of the sample measurements contributed to only 14% of the total variance. The expanded uncertainty associated with the reference value was 3.4 % relative.
When evaluated against the reference value, 29 of the 30 participants obtained satisfactory z-scores, and 23 participants obtained satisfactory En-scores. While the participant results were generally in agreement with the reference value, those participants with unsatisfactory En-scores may have underestimated their measurement uncertainty. The robust average of participant results is biased low from the spiked value. The reference value confirms that this is only an apparent bias and that the participant methods are generally accurate for PFOA in this sample.
The analytical demand for PFAS analysis continues to grow with an ever increasing list of analytes and matrices. The lack of high order SI traceable calibrators constrains provision of accuracy based PT to very few analytes. It will be beneficial for National Metrology Institutes and the International Bureau of Weights and Measures (BIPM) to consider the importance of developing capabilities which would support laboratories world wide and ensure quality of PFAS testing in food and water.
Regulatory assessment of per- and polyfluoroalkyl substances (PFASs) in European surface waters is shifting from a single-compound environmental quality standard (EQS) for perfluorooctane sulfonic acid (PFOS) toward a potency-weighted sum of 25 PFASs criterion under the revised Water Framework Directive (WFD). This env...
G. Schertzinger, Raquel González de Vega, Viktoria Müller et al.· Toxics· 0 citations
Background: Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants of increasing concern due to their widespread occurrence, environmental persistence, and potential adverse health effects. Monitoring PFAS in drinking water is important for consumer safety and quality assurance, particular...
Introduction Biomonitoring of commercial endocrine-disrupting chemicals (EDCs) increasingly underpins exposure assessment and risk evaluation, yet most large-scale studies still rely on indirect, enzymatic hydrolysis–based methods whose quantitative performance has not been systematically verified. Here, we describe th...
R. Gerona, Alia Sovereign, Patricia Hunt· Frontiers in Chemistry· 0 citations
N-nitrosamine impurities found in the global pharmaceutical supply chain have forced an urgent transformation in the development of risk-based analytical monitoring and advanced quality control standards. The pivotal 2018 finding of the compound N-nitrosodimethylamine in the "sartan" drug class prompted the transition...
Santosh Bhende, A. Phatak, P. Chaudhari· International Journal of Pha...· 0 citations
Targeted analytical methods are widely used to quantify per- and polyfluoroalkyl substances (PFAS) in combustion flue-gas. However, interpretation of PFAS emission data is challenged by high shares of non-detects (NDs), heterogeneous limits of quantification (LoQs), and extensive target analyte lists. This study evalua...
M. Wexler, Vanessa Nuredin, H. Gehrmann et al.· Waste Management· 0 citations
As daily essentials for skin protection and cosmetic enhancement, personal care products (PCPs) are used extensively worldwide. Due to their direct and prolonged contact with the skin, any hazardous ingredients they contain warrant serious attention. Although bisphenols (BPs) and alkylphenols (APs) are of growing conce...
Shu-Yan Sun, Ya-Lei Dong, Ming Jin et al.· Analytical Methods· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.