Aug 2026· Occupational Safety in Industry· pp. 56-62· 0 citations
Abstract
The study focuses on the emergence of ignition sources in low-voltage cable lines under uncontrolled neutral overload caused by higher-harmonic currents and asymmetry. The goal of the study is to develop a quantitative assessment methodology to estimate the probability of local inter-conductor insulation breakdown, accounting for its current technical condition and thermal aging dynamics.
The study is based on the synthesis of deterministic thermophysical analysis and stochastic modeling. A Markov model of four stages of insulation reliability is proposed, where the Arrhenius equation determines the transition intensities. The instantaneous risk of ignition source emergence is calculated based on the Weibull distribution. A concept of a dynamic thermal strength threshold has been proposed, which is not constant but decreases as a function of the insulation's thermal degradation. A stochastic algorithm that helps transform electrical mode parameters into an integral index of the probability of ignition source generation, considering the thermal history of a particular line, has been developed.
Through a numerical experiment, it has been proven that the ignition source generation is physically impossible for new electrical wiring and that it becomes inevitable under a similar thermal impact on the insulation that has lost its properties. Under an identical load in the neutral, a new cable line maintains its dielectric integrity, whereas worn insulation reaches a critical level of fire hazard within the first 50 minutes of impact. Notably, traditional phase-circuit protection means are functionally incapable of detecting this emergency mode.
The presented mathematical framework allows for quantitative substantiation of ignition source generation under overloads, demonstrating the shift of critical threshold temperatures into the operating range as insulation ages. The proposed method enables predictive protection of electrical grids by timely detection of critical proximity between the working temperature and the dynamic dielectric strength threshold, preventing inter-conductor faults. The algorithm can be integrated into electric installation intellectual monitoring systems for predictive prevention of fires in grids with a high proportion of nonlinear loads.
The increasing demand for reliable underground transmission systems requires accurate evaluation of thermal performance and insulation aging in high-voltage cables. This paper presents an integrated framework for the service-life assessment of 132 kV underground cables in duct-bank configurations. The approach combines...
Bruno B. Ramirez Ponce, J. E. Guevara Asorza, R. D. de Araujo et al.· IEEE Access· 0 citations
Air circuit breakers are critical protective devices in low-voltage distribution systems, and their reliability is considered to have significant influence on the operation of such systems. With respect to the electrical performance degradation of air circuit breakers, the relationship between the change in over-travel...
Bokai Hu, Likai Geng, Yao Wang et al.· Processes· 0 citations
Electrochemical corrosion is one of the main causes of degradation of substation grounding devices and directly impacts the operational reliability of electric power facilities. Despite numerous studies on individual corrosion factors, comprehensive models considering the combined effects of soil physical and chemical...
S. Voytkevich, V. Kaverin, Leonid Daich et al.· Applied Sciences· 0 citations
The deployment of floating offshore wind systems in deeper waters introduces additional challenges for subsea power cables due to complex mechanical, environmental and operational factors. Among these, ensuring the longevity of cables requires a reliable fatigue damage assessment, which this study addresses by applying...
Kjetil André Karlsen-Husøy, M. Asyikin, Jon Andreas Årstein· Journal of Marine Science an...· 0 citations
Reliable operation of medium-voltage distribution networks critically depends on the integrity of cross-linked polyethylene (XLPE) insulated cables. This paper proposes a diagnostic methodology that integrates leakage current (LC) measurement with phase-resolved partial discharge (PRPD) analysis to assess cable insulat...
K. Janprom, Sittadach Morkmechai, Natchanun Prainetr et al.· International Journal of App...· 0 citations
Conventional overload verification of bimetallic protection elements requires long-duration current loading and considerable time and energy consumption. This study proposes a rapid verification method combining a first-order thermodynamic equivalence model with image-based deflection measurement. Local linear interpol...
Hong Ren, Jianqiang Li, Xin Ru et al.· Electronics· 0 citations