Impact of power cable modelling on switching transient overvoltage analysis in medium voltage motors

Sep 2026 · International Journal of Applied Power Engineering (IJAPE) · Vol 15, pp. 1233 · 0 citations · 22 references

Abstract

Precise electrical cable representation is crucial for examining surge transient overvoltages in medium voltage (MV) motor systems. These brief overvoltages, initiated by swift switching actions, may induce substantial insulation strain, equipment degradation, and potential system failures. This study explores the influence of different power cable modeling techniques on transient overvoltage characteristics in MV motors during switching operations. Various modeling techniques, such as aggregated parameter, spread parameter, and frequency-dependent models, are evaluated for their effectiveness in inward capturing transient phenomena. Simulation studies using industry-standard electromagnetic temporary (EMT) assessment instruments evaluate the effect of these simulation methods on voltage spikes, shape distortions, and rise times. The discoveries indicate that exact electrical wire depiction is pivotal in molding, fleeting reactions, emphasizing the significance of choosing suitable simulation methods for efficient insulation coordination and system protection. This research provides valuable guidance for power system engineers, helping them mitigate transient overvoltage risks and improve the reliability of MV motor applications. Also, this study demonstrates electrical cable simulation that can impact the advice and verdicts obtained from moderate voltage motor.

Read PDF

Similar papers

Conference Sep 2026

Parameterizing DC Circuit Breaker Interruption Characteristics for Mapping HVDC Cable Transient Stress Regimes

The transition from point-to-point HVDC links to multiterminal HVDC (MT-HVDC) grids increases the need to understand how the interruption of DC current shapes transient dielectric stress on connected cable systems. This paper develops a compact parameterization of the DC circuit breaker–cable interface in a reduced 525...

T. Karmokar, Arjan Van Schijndel, Marjan Popov · 0 citations
Open access 2026

Vector modeling of the transient process in an electric network with a voltage of 6-10 kV under the action of an automatic transfer switch

Introduction. In 6-10 kV electrical networks with high-power induction motors, emergency modes accompanied by voltage sags, motor starts, and self-starts significantly reduce the reliability of power supply. The selection of the Automatic Transfer Switch (ATS) operating speed is of particular importance, as the superpo...

B. A. Korobeinikov, A. M. Oppakhodzhaev, D. I. Sidorov · 0 citations
Open access Aug 2026

Experimental Investigation of the Impact of Cable Length and Type on Motor Overvoltages, Shaft Voltage, and Bearing Currents in PWM-Inverter-Fed Drive Systems

Fast-switching transients and high dv/dt associated with PWM inverters exacerbate the reflected-wave effects in the motor feeder cable. This leads to higher motor-side overvoltages, which increase the stress on the motor winding insulation, potentially accelerating insulation degradation and increasing the risk of part...

Fawzy A. Abdo, Mehmet Güleç, Kotb B. Tawfiq et al. · 0 citations
Open access Sep 2026

Condition assessment of medium voltage cable insulation using leakage current and phase-resolved partial discharge

Reliable operation of medium-voltage distribution networks critically depends on the integrity of cross-linked polyethylene (XLPE) insulated cables. This paper proposes a diagnostic methodology that integrates leakage current (LC) measurement with phase-resolved partial discharge (PRPD) analysis to assess cable insulat...

K. Janprom, Sittadach Morkmechai, Natchanun Prainetr et al. · 0 citations
Conference Sep 2026

Voltage-Only Modal Diagnostics of Internal Short-Circuit Faults in Inverter-Cable-Machine Systems Using Transient Response Analysis

Wide-bandgap (WBG) inverter drives impose repetitive high-frequency voltage stress, accelerating insulation degradation and increasing the probability of short-circuit faults in cables and machine windings. However, existing online diagnostic approaches face significant deployment barriers due to their sensitivity to e...

Yue Yu, Hu-Jun Peng, S. Steentjes · 0 citations
Open access Oct 2026

Investigation of Resonance Condition in OFF Shore Wind Park during Energization Events

Transformer energisation in offshore High-Voltage Alternating Current (HVAC) transmission systems can result in significant transient and temporary overvoltages due to the interaction between transformer magnetising inrush currents and network resonances. A detailed Electromagnetic Transient (EMT) model comprising a Th...

M. Jyothi, C. V. K. Bhanu · 0 citations