Sep 2026· Journal of Arthroplasty· 0 citations· 17 references
Medicine
TL;DR
While periarticular hardware retention in conversion TKA was associated with increased operative time, blood loss, and early complications, especially with plates or intramedullary nails, it was not associated with higher reoperation rates or two-year patient-reported outcomes.
Abstract
Background
Total knee arthroplasty (TKA) in the setting of retained periarticular hardware presents technical challenges and may influence surgical complexity and outcomes. This study aimed to evaluate whether hardware retention at the time of conversion TKA impacts reoperation risk, perioperative outcomes, and patient-reported outcome measures.
Methods
A retrospective cohort study was conducted of 320 patients who underwent conversion or primary TKA between 2009 and 2019. Patients were categorized into three groups: no retained hardware (n = 171), retained "minor" hardware (n = 90), and retained "major" hardware (n = 59), based on intraoperative complexity. The primary outcome was risk of reoperation and was assessed using a risk-adjusted Fine-Gray subdistribution hazard model that adjusted for death as a competing event. The secondary outcomes included operative time, blood loss, lengths of stay, complications, and patient-reported outcome measures (University of California, Los Angeles (UCLA) Activity Score, Veterans RAND 12-Item (VR-12) Health Survey Physical and Mental Component Scores) were assessed using univariate tests.
Results
There were no significant differences in the risk of reoperation among the three groups (multivariable Fine-Gray analysis: P = 0.162). Operative time and blood loss were significantly higher in the major hardware group (P < 0.001). Lengths of stay and complication rates also varied across groups (P < 0.05). The PROMs at one and two years showed minor differences, with lower improvements in VR-12 Mental Scores and UCLA scores in the major hardware group at one year (P = 0.034 and P = 0.016, respectively).
Conclusion
While periarticular hardware retention in conversion TKA was associated with increased operative time, blood loss, and early complications, especially with plates or intramedullary nails, it was not associated with higher reoperation rates or two-year patient-reported outcomes.
Abstract Patellar resurfacing in primary total knee arthroplasty (TKA) has been debated for decades. This study aimed to evaluate cost-effectiveness and clinical outcomes of patellar resurfacing in modern TKA at a high-volume arthroplasty center. A retrospective study was conducted on 4,534 patients who underwent unila...
Anzar Sarfraz, Garrett L. Ruff, B. Schaffler et al.· The journal of knee surgery· 0 citations
STUDY DESIGN
Retrospective cohort study.
OBJECTIVE
To evaluate the association between iliac fixation and long-term reoperation risk in patients undergoing multilevel lumbosacral fusion for degenerative pathology.
SUMMARY OF BACKGROUND DATA
Spinopelvic fixation using iliac screws is commonly employed to improve con...
K. Majid, Richard N. Chang, Samear Asefi et al.· Spine· 0 citations
BACKGROUND
Whether early surgery reduces mortality in revision total hip arthroplasty (THA) for periprosthetic proximal femur fractures (PPFF) remains unclear. The aim of this study was to evaluate the association between time to surgery and short- and long-term outcomes following PPFF.
METHODS
Using a large national...
Aidan G. Papalia, Robert G. Ricotti, Nicholas Frappa et al.· Journal of Arthroplasty· 0 citations
BACKGROUND
The purpose of this study was to identify risk factors associated with wound complications following DAA THA and to evaluate the incidence of these wound issues when negative pressure wound therapy (NPWT) was used as the primary surgical dressing.
METHODS
We reviewed 725 patients from five different surgeo...
B. Schaffler, M. Haider, A. Manjunath et al.· HIP International· 0 citations
Preoperative infection control and an individualized approach to postoperative weight-bearing appear as key modifiable factors to improve early outcomes in periprosthetic femoral fractures.
Nicolas Blum, Lise Chevassut, G. Leclerc et al.· European Journal of Orthopae...· 0 citations
Background: Hip resurfacing arthroplasty (HRA) was developed as a bone-preserving alternative to conventional total hip arthroplasty (THA), particularly for young and physically active patients. However, concerns regarding metal-on-metal bearings have substantially restricted its use. This study evaluated the long-term...
G. Rovere, Davide Luziatelli, Sandro Luziatelli et al.· Applied Sciences· 0 citations