A rigorous clinical stress test for multimodal model editing that evaluates whether an edit remains reliable, precise, and generalizable under the challenges of image and text variation, modality and protocol shifts, clinical knowledge composition, and temporal progression is introduced.
Abstract
Model editing promises a fast, targeted way to correct post-deployment mistakes in medical vision-language models (VLMs) without costly retraining. However, existing multimodal model editing benchmarks focus on general-purpose tasks and do not reflect realistic clinical domain requirements and variability. To address this, we introduce M3Bench, a clinically grounded benchmark for multimodal model editing that evaluates whether an edit remains reliable, precise, and generalizable under the challenges of image and text variation, modality and protocol shifts, clinical knowledge composition, and temporal progression. M3Bench contains 16,276 questions spanning diverse anatomy, modalities, and specialties, and supports both single and sequential edits. By evaluating 4 representative editors across 6 medical and general VLMs, we find that no method excels across all criteria. Gradient-based editors achieve strong transfer but suffer from catastrophic locality violations, whereas memory-based methods preserve locality but lack compositional generality and exhibit high backbone-dependent hyperparameter sensitivity. We further attribute these failures to the latent space geometry of VLMs and how different editing methods shift its landscape. Overall, M3Bench establishes a rigorous clinical stress test for multimodal model editing and offers actionable guidance for safer post-deployment adaptation. The benchmark is publicly available at https://github.com/BioMed-AI-Lab-U-Michgan/M3Bench .
A clinically curated Pan-Asia WSI--report dataset is introduced and the REG 2025 benchmark is established as a benchmark for evaluating WSI-based structured report generation and vision-language understanding in computational pathology, providing insights for the design of clinically grounded multimodal pathology model...
Yu-Mi Lee, Harim Oh, Hyo-yun Kim et al.· 0 citations
A framework that strengthens clinical alignment by separating and enhancing training-time alignment and inference-time alignment is proposed and experiments show that complementary visual representations with a multi-encoder design and concept-level auxiliary learning help preserve clinically meaningful information.
Yunseo Lee, Hyun Jun Kim, Heeseung Shin et al.· 0 citations
The underlying causes of miscalibration in VLMs and Medical-VLMs are investigated and a simple train-time calibration method, Multi-Class Margin (MCM) regularization, is proposed, which achieves lowest ECE on 10 out of 12 settings in in-domain and remains competitive under domain shifts.
HCE-CLIP is proposed, a vision–language pretraining framework that formulates medical image–text alignment as a hierarchical label-conditional energy modeling problem and introduces a hierarchical contradiction-based metric that quantifies logical inconsistencies between fine-grained disease predictions and higher-leve...
Cheng-Sheng Mao, Yuan Luo· Proceedings of the Thirty-Fi...· 0 citations
The results indicate that confidence-guided masked diffusion with reliability-aware decoding is a useful direction for controllable and reliability-aware clinical assistants.
Saqib Qamar, Goram Mufarah M. Alshmrani· Technologies· 0 citations
A large-scale structured reasoning dataset constructed via a novel slice-wise data synthesis paradigm that unlocks deep volumetric understanding and highly interpretable clinical logic without requiring computationally expensive 3D-specific pre-training is introduced.