In this prospective cohort, a noise-adapted AI-ECG algorithm identified SHD phenotypes from real-world single-lead Apple Watch ECGs and improved screening efficiency, supporting a potential role for wearable ECG-based screening in the scalable identification of clinically actionable SHD.
Abstract
Importance: Consumer wearables such as the Apple Watch can record single-lead electrocardiograms (ECGs) but are used mainly to detect rhythm disorders. Artificial intelligence-enhanced ECG (AI-ECG) could extend these real-world recordings for detecting structural heart disease (SHD), yet prospective validation remains limited. Objective: To prospectively validate a previously developed, noise-adapted AI-ECG model for detecting severe SHD from single-lead Apple Watch ECGs. Design: Prospective cohort study. Setting: Yale New Haven Hospital echocardiography laboratory. Participants: Adults aged >=18 years undergoing outpatient transthoracic echocardiography (TTE) as part of routine clinical care. Exposure: A 30-second, single-lead Apple Watch ECG recorded during the TTE visit and processed through an end-to-end, HIPAA-compliant platform for real-time AI-ECG inference. Main Outcomes and Measures: The primary outcome was discrimination for TTE-defined severe SHD, a composite of left ventricular systolic dysfunction (left ventricular ejection fraction <40%), severe left-sided valvular disease, and/or severe left ventricular hypertrophy, assessed by the area under the receiver operating characteristic curve (AUROC). Secondary measures were sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) at prespecified thresholds, and screening efficiency, assessed by the number needed to test (NNT) under usual-care versus AI-ECG-guided strategies. Results: Among 596 participants with analyzable Apple Watch ECGs (median age, 62 years [IQR, 46-72]; 51.2% women), severe SHD was present in 30 (5.1%). The model discriminated severe SHD well (AUROC, 0.841; 95% CI, 0.761-0.921), with a sensitivity of 76.7% (59.1-88.2), specificity of 83.2% (79.9-86.1), NPV of 98.5% (97.0-99.3), and PPV of 19.7% (13.5-27.8) at the prespecified threshold. An AI-ECG-guided strategy reduced the NNT to identify one case by more than 60% versus usual care across the composite and individual SHD phenotypes. Conclusions and Relevance: In this prospective cohort, a noise-adapted AI-ECG algorithm identified SHD phenotypes from real-world single-lead Apple Watch ECGs and improved screening efficiency. These findings support a potential role for wearable ECG-based screening in the scalable identification of clinically actionable SHD.
BACKGROUND
Left ventricular hypertrophy (LVH) is an independent predictor of cardiovascular morbidity and mortality. Single-lead electrocardiogram (ECG) tracings from consumer wearable devices may enable scalable screening for LVH where standard 12-lead ECG acquisition is not feasible.
METHODS
We developed a transfor...
Shahana Nandy, Sneha Nandy, Siddhartha R. Dalal· Proceedings· 0 citations
Traditional 12-lead ECGs offer comprehensive insights into the electrical activity of the heart, but require clinical settings and expert interpretation, which limits their accessibility. Smartwatch 1-lead ECGs can be recorded at home, allowing more frequent and rapid monitoring, opening opportunities for early adver...
V. van der Valk, D. Atsma, Roderick W. C. Scherptong et al.· npj Cardiovascular Health· 0 citations
Aims: Structural heart disease (SHD) often remains undetected until symptoms develop. Portable 1-lead ECG devices return an automated rhythm-based interpretation, but whether AI-ECG adds diagnostic value beyond this interpretation is unknown. We prospectively evaluated a noise-adapted 1-lead AI-ECG algorithm for detect...
A. Aminorroaya, S. Shankar, Mariam Khan et al.· medRxiv· 0 citations
The 12-lead electrocardiogram (ECG) is inexpensive, noninvasive, and widely available, but conventional interpretation may not capture subtle signals related to cardiac structure, systemic physiology, and future risk. This review examines the use of deep learning–enabled ECG analysis beyond conventional arrhythmia dete...
Shlomo Shaulian, R. Zeltser, A. Makaryus· Diagnostics· 0 citations
Atrial fibrillation (AF) detection from short single-lead electrocardiogram (ECG) recordings requires a balance between rhythm discrimination and computational efficiency. This study compares a one-dimensional ResNet-34 (1D-ResNet34), a Temporal Convolutional Network (TCN), and MambaECG, a compact Mamba-inspired gated...
Hamim Islam Hellol, Md Al Ridwan, Md Shahnawaj et al.· BioMedInformatics· 0 citations