CliniCARE-Bench is the first deployment-oriented clinical-agent benchmark to jointly evaluate real longitudinal EHR investigation, claim-level evidence grounding, governing-policy use, process adherence, and calibrated abstention within a common patient-level adjudication framework.
Abstract
Large language models perform strongly on medical knowledge benchmarks, but reliable clinical deployment requires agents to conduct defensible investigations over heterogeneous, longitudinal records: determining what evidence is needed, retrieving and reconciling structured and free-text data, grounding conclusions in verifiable evidence, and deferring cases that cannot be resolved reliably. We introduce CliniCARE-Bench (Clinical Calibrated Audit of Medical Reasoning in EHR), a benchmark for retrospective clinical audit: 25 clinician-validated scenarios instantiated as 750 patient-specific cases over real-patient-derived MIMIC-IV data. Systems investigate each case through a governed, logged tool environment for record retrieval, computation, and policy access, and return one of four verdicts---Yes, No, Indeterminate: Lack of Data, or Indeterminate: Medically Ambiguous---the last two separating missing evidence from residual medical ambiguity. Beyond verdict accuracy, we score patient-evidence and policy grounding, process adherence, calibrated abstention, reliability, and efficiency against case-level reference verdicts produced by independent multi-model adjudication and calibrated against Clinical Board review. Every retrieval, computation, and report is replayable, so the investigation trace is inspectable and scorable. To our knowledge, CliniCARE-Bench is the first deployment-oriented clinical-agent benchmark to jointly evaluate real longitudinal EHR investigation, claim-level evidence grounding, governing-policy use, process adherence, and calibrated abstention within a common patient-level adjudication framework. Across 16 agentic systems, four-way accuracy spans 65.3-76.1%, but raw accuracy overstates investigation quality. Defect-free accuracy, which credits a verdict only when correct and free of prohibited shortcuts, is 4.8-14.8 points lower and reorders the leaderboard.
Clinical decisions, such as diagnosing conditions, prescribing medications, and recommending procedures, are rarely made with absolute certainty. Instead, they reflect probabilistic judgments shaped by evolving patient information and incomplete evidence. However, current EHR systems and knowledge graphs encode such de...
Kexuan Xin, Guillaume Pelat, Jonathan Vitale et al.· International Conference on...· 0 citations
This formative study establishes a methodological foundation and conceptual framework to guide subsequent validated, large-scale EHR-inconsistency analysis and proposes a graded ontology spanning strict contradiction and ambiguity, with a schema characterizing each flagged case by category, section, domain, and inconsi...
Jiankang Lu, Panyu Chen, Miriam M. Treggiari et al.· arXiv.org· 0 citations
Ask-Audit-Apply (AAA) is proposed as a clinician-facing framework for AI-supported clinical reasoning that specifies decision-level behavioral practices that may support education, supervision, and future research on safe AI integration across a range of CDS tools as these systems increasingly participate in clinical c...
Andrew Jenkins, Katherine W. Eisenberg, R. Ziegelstein· Journal of general internal...· 0 citations
CLINLENS is introduced, a benchmark of 200 executable tasks over five linked MIMIC resources spanning structured electronic health records, notes, electrocardiograms, chest radiographs, and echocardiograms, which exposes a substantial gap between runnable submissions and correct clinical analyses.
Yuan Zhu, Ethan B. Liu, Frank Nie et al.· arXiv.org· 0 citations
SynTrustBench is introduced, an evidence-gated and executable benchmark for evaluating trustworthiness claims across five non-compensable dimensions: fidelity, clinical utility/validity, privacy, equity, and robustness/generalization.
This Perspective concerns the most consequential of these applications: the autonomous triage of self-presenting, undifferentiated patients, with little or no clinician in the loop, and the evidence of safety does not yet exist.
Shayndhan Sivanathan, Shravan Nageswaran, Mehdi Zadem et al.· arXiv.org· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.