Aug 2026· Bioengineering· Vol 13, pp. 924· 0 citations· 37 references
Medicine
TL;DR
It is demonstrated that temporal label expansion enables accurate GRU-based gait event detection and temporal gait analysis from data collected with a single smartphone IMU, indicating the need for adaptation across datasets.
Abstract
Accurate gait event detection using inertial measurement units (IMUs) is essential for temporal gait analysis, but frame-level detection is challenged by sparse initial contact (IC) and foot-off (FO) events. This study evaluated recurrent neural network architectures and training strategies for simultaneous IC and FO detection using a single shank-mounted smartphone IMU. The internal dataset included 28 healthy older adults and 18 individuals with non-specific low back pain (NSLBP). Temporal label expansion substantially improved validation performance for gated recurrent unit (GRU) and long short-term memory models, whereas point-label and class-weighted training performed poorly. The selected label-expanded GRU (LE-GRU) achieved F1 scores above 0.95 for both events and mean absolute temporal errors below 12 ms on held-out internal test folds, with high performance in both cohorts. On an external dataset with different sensor and acquisition characteristics, high performance required full-network fine-tuning, indicating the need for adaptation across datasets. Stance phase and stride time calculated from LE-GRU-predicted events showed high agreement with reference-derived values, with Lin’s concordance correlation coefficients from 0.980 to 0.994. These findings demonstrate that temporal label expansion enables accurate GRU-based gait event detection and temporal gait analysis from data collected with a single smartphone IMU.
Pathological gait classification plays an important role in objective motor function assessment, early clinical screening, and rehabilitation evaluation. However, traditional clinical gait assessment methods are highly dependent on expert experience and may fail to detect subtle gait abnormalities. Moreover, existing i...
A novel, real-time gait abnormality detection system that leverages deep learning and an intelligent wearable insole to overcome limitations associated with conventional gait assessment methods is introduced.
Anas Mohd Noor, Nur Rabiatul Adawiyah Veran, Ainnur Natasha Jamri· Journal of Engineering Techn...· 0 citations
Osteonecrosis of the femoral head (ONFH) often presents with nonspecific early symptoms, which may lead to missed or delayed diagnosis. Gait abnormality is an important functional manifestation of ONFH, and wearable inertial measurement unit (IMU)-based gait analysis may provide a portable and non-invasive approach for...
Zhi-Chao Wu, Xiao-Yu Shang, Jian-Xiong Ma· Medical Engineering and Phys...· 0 citations
This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided refe...
Wearable inertial measurement units (IMUs) provide a practical and privacy-preserving sensing modality for lower-limb activity recognition in assistive robotics, rehabilitation monitoring, and movement analysis. However, many IMUbased human activity recognition methods model multichannel sensor streams mainly as flat t...
Alvarado Morales Lisbeth Katherine, Qi-Fei Wu, Guoyu Zuo et al.· IEEE/ASME International Conf...· 0 citations
The proposed DL-based markerless video system demonstrated high agreement with Tracker for gait speed assessment during the 10-MWT under outdoor non-laboratory conditions, supporting its potential as an accessible approach for gait speed assessment.
T. Kamnardsiri, Phasit Charoenkwan, S. Boripuntakul· Journal of Functional Morpho...· 0 citations