Skip to content

Gait spatial parameter estimation from smart insoles using deep learning in a large heterogeneous clinical population

Sep 2026 · ACM Transactions on Computing for Healthcare · 0 citations · 50 references

TL;DR

The proposed smart insole-based gait parameter estimation approach that includes diverse health conditions while minimizing feature engineering and eliminating the need for demographic or anthropometric inputs showed excellent agreement with the reference system across walking speeds and evaluation levels.

Abstract

While achieving reasonable accuracy, prior smart insole-based approaches for gait parameter estimation have been limited by small sample sizes, narrow clinical settings, and reliance on demographic or anthropometric priors. These limitations restrict their generalizability to heterogeneous real-world populations with diverse gait characteristics. Thus, this study proposes a smart insole-based gait parameter estimation approach that includes diverse health conditions while minimizing feature engineering and eliminating the need for demographic or anthropometric inputs. Using minimally engineered inertial measurement unit signals obtained from smart insoles worn by 702 individuals with diverse neurological and musculoskeletal conditions, a Conformer-based deep learning network was developed to estimate four spatial gait parameters: stride length, step length, stride width, and step width. The performance of the proposed approach was evaluated against the GAITRite walkway system and compared with previously suggested approaches, with additional evaluation using a publicly available dataset. The proposed approach showed excellent agreement with the reference system across walking speeds and evaluation levels. For example, subject-wise estimation of step length at the usual speed achieved a mean absolute error of 1.33 cm (ICC = 0.99). Scatter and Bland-Altman analyses further demonstrated strong agreement between the proposed approach and the reference system. These results highlight the potential of wearable smart insoles combined with deep learning for scalable gait parameter estimation.

View source

Similar papers

Open access Sep 2026

Smart Insole with Deep Learning for Real-Time Classification of Gait Abnormalities

A novel, real-time gait abnormality detection system that leverages deep learning and an intelligent wearable insole to overcome limitations associated with conventional gait assessment methods is introduced.

Anas Mohd Noor, Nur Rabiatul Adawiyah Veran, Ainnur Natasha Jamri · 0 citations
Open access Sep 2026

Machine learning-based identification of a minimal wearable sensor for gait assessment in vestibular schwannoma

Vestibular schwannoma (VS) impairs balance and gait, often leading to substantial functional limitations that are incompletely captured by standard clinical assessments. While wearable inertial sensors and machine learning offer promise for objective gait analysis, clinical translation is limited by uncertainty r...

Lou C. Kohler Voinov, Sergio Sánchez-Manso, Raabeae Aryan et al. · 0 citations
Oct 2026

HeadLite: Compact Multimodal Sensor Fusion for Stride Length Estimation From Smart Insoles

Smart insoles provide a practical platform for ambulatory stride length estimation by combining inertial and plantar-pressure sensing. Stride length is an informative spatial gait marker linked to mobility, stability, and fall risk, and estimating it from a compact, low-power wearable is a prerequisite for continuous g...

Yeonghwan Kim, Changhwan Choi, K. Yoo et al. · 0 citations
Open access Oct 2026

A contactless and AI-assisted sensor for gait assessment of stroke patients.

The gait parameters, i.e., gait speed, stride length, step length, and cadence, serve as key indicators for patients with mobility impairments. Monitoring these parameters can significantly aid in assessing recovery progress, especially in stroke patients. Compared to traditional clinical visits, wearable sensors, or m...

Zhuang-Zhuang Gu, Ryan Titus, Hem Regmi et al. · 0 citations
Open access Sep 2026

Instrumented Walkway Gait Analysis Predicts Fallers in Neurological Disorders: Identifying Digital Biomarkers for Balance Monitoring

Assessing balance is crucial in neurological rehabilitation, yet while wearable sensors enable real-world monitoring, identifying reliable digital biomarkers remains challenging. This study utilized a high-fidelity instrumented walkway to determine which gait parameters best predict balance impairment, providing robust...

Victor S. You, Leland Barnard, H. Botha et al. · 0 citations
Preprint Sep 2026

SynthGait-19K: A Physically Grounded Synthetic Video Dataset for Gait Parameter Estimation

Accurate estimation of clinically meaningful gait parameters from monocular video is important for scalable mobility assessment, yet progress is limited by the small scale, restricted viewpoints, and limited visual diversity of existing datasets. We introduce SynthGait-19k, a physically grounded synthetic video dataset...

Soroush Mehraban, Xin-Lei Lin, Vida Adeli et al. · 0 citations