The value of "Black-Bone" MR imaging in pediatric spondylolysis: impact on diagnostic confidence and accuracy in experienced and non-experienced readers.
INTRODUCTION
Lumbar spondylolysis is a common cause of low back pain in adolescents, yet early and confident diagnosis often requires CT, exposing patients to radiation. The Black-Bone (BB) MR sequence is a 3D low-flip-angle gradient-echo (GRE) acquisition designed to enhance bone-soft tissue contrast. This study assessed whether adding BB to a standard pediatric lumbar MRI protocol improves diagnostic accuracy, interreader-agreement, and confidence.
Methods
Forty-four adolescents (mean age, 12 years; 23 girls, 21 boys) with suspected spondylolysis underwent lumbar MRI including BB, with radiographs and/or CT as reference standard. Thirty patients had confirmed spondylolysis and 14 served as controls. Four blinded readers (2 senior neuroradiologists, 2 residents) independently reviewed all cases twice: first with standard MRI only, then with BB included. Readers scored each pars interarticularis level and side (0 = negative, 1 = probable, 2 = definite). Interrater agreement (weighted Cohen's κ), sensitivity, specificity, PPV, NPV, and accuracy were calculated.
Results
BB improved interrater agreement across all pairs (κ 0.81-0.93 vs. 0.59-0.82 pre-BB). Sensitivity increased for all readers (+ 5-12% points), while specificity remained high (0.89-1.00). PPV was consistently excellent (0.93-1.00), and NPV improved with BB (0.83-0.87 vs. 0.75-0.83 pre-BB). Ambiguous ratings dropped from 58 pre-BB to 5 post-BB, resolving > 90% of indeterminate assessments. Accuracy increased by approximately 2-5% points, whereas diagnostic confidence showed a larger improvement.
Conclusion
Incorporating BB into pediatric lumbar MRI protocols improved interreader agreement and diagnostic confidence while markedly reducing equivocal interpretations. Although diagnostic performance metrics improved, these findings should be interpreted cautiously given the limited CT correlation. BB may represent a practical radiation-free adjunct to standard MRI for evaluating suspected pediatric spondylolysis.
3 T zero echo time MRI showed high inter-rater reproducibility for pars-defect detection and may serve as a reproducible, radiation-sparing adjunct to lumbar MRI rather than a replacement for CT, and require confirmation in larger studies.
Müjgan Orman, Deniz Çeliker, Bera Koca et al.· Skeletal Radiology· 0 citations
CT remains the imaging reference standard for evaluating structural sacroiliac joint (SIJ) lesions in spondyloarthropathy (SpA), but its use is limited by ionizing radiation. This retrospective single-center study evaluated a CT-like multi-echo 3D gradient-echo MRI sequence (FRACTURE) for structural SIJ assessment by c...
Etienne Leroux, David Fadli, P. Spinnato et al.· Life· 0 citations
Abstract Objective To evaluate diagnostic agreement between ultrasonography (US) and magnetic resonance imaging (MRI) in suspected hip abductor pathology, and to assess the impact of body mass index (BMI) on this agreement. Methods From September 1, 2005, to March 11, 2025, patients evaluated for lateral hip pain at a...
Pranav Rajaram, Steven B. Soliman, Liam A. Peebles et al.· Journal of Hip Preservation...· 0 citations
Isthmic spondylolisthesis is prevalent among adolescent athletes (AA). Upright MRI (uMRI) offers a radiation-free alternative to radiographs, combining imaging of the loaded spine with detailed depiction of the adjacent structures. This study evaluates the feasibility and intra-rater measurement repeatability of sp...
M. Cassel, T. Joost, Chase Slater et al.· Frontiers in Radiology· 0 citations
Background
Osteoporosis is frequently unrecognised in patients undergoing rotator cuff repair. Shoulder magnetic resonance imaging (MRI), already standard of care, offers an opportunity for opportunistic osteoporosis screening.
Objective
To evaluate whether proximal humeral cortical bone thickness on shoulder MRI can...