Sep 2026· Journal of Visualized Experiments· Vol 235· 0 citations
Medicine
TL;DR
The modular magnetic design provides staged osteotomy guidance and may reduce the need for repeated adjustments, unnecessary bone removal, and soft-tissue manipulation, which is consistent with vascular-preserving principles, although segment perfusion was not directly assessed.
Abstract
This study introduces the design and clinical application of a novel magnetic-connection digital osteotomy guide to enhance the precision and efficiency of segmental maxillary osteotomy. Segmental Le Fort I osteotomy is an essential technique for correcting complex transverse and vertical dental-maxillofacial deformities, yet traditional methods involving manual plaster model surgery are prone to significant errors. To address these challenges, this protocol integrates virtual surgical planning (VSP) using CT scans and specialized modeling software to create a patient-specific, 3D-printed two-part guide system. The primary component is designed to guide the horizontal Le Fort I osteotomy and bilateral premolar extraction lines. Once the maxilla is down-fractured, a secondary segmental guide is connected to the primary component via four embedded neodymium magnets, each measuring 3 mm in diameter and 1.5 mm in thickness. This magnetic connection provides a stable, rapid, and interference-free attachment that allows for precise guidance of palatal and midline osteotomy lines. This protocol demonstrates the clinical application of a modular magnetic guide system for transferring the virtual osteotomy plan in patients with maxillary protrusion and arch width discrepancies. Postoperative color-map analysis showed local surface deviations of approximately 0.5-0.9 mm around the visible osteotomy margins, supporting the preliminary accuracy of osteotomy-region transfer. The modular magnetic design provides staged osteotomy guidance and may reduce the need for repeated adjustments, unnecessary bone removal, and soft-tissue manipulation, which is consistent with vascular-preserving principles, although segment perfusion was not directly assessed. Neodymium magnets are biocompatible, maintain stability after sterilization, and are cost-effective due to their reusability. Despite the potential fragility of current three-dimensional (3D)-printed resin materials, the magnetic connection digital osteotomy guide offers significant clinical value by bridging the gap between virtual planning and surgical execution. This method ensures highly accurate bone removal and positioning, representing a promising advancement for complex orthognathic surgical procedures.
Orthognathic surgery has increasingly incorporated digital workflows and patient-specific surgical guides to enhance accuracy and predictability. While these technologies offer improved planning and execution, their intraoperative application in segmented maxillary osteotomies remains technically demanding. Limited lit...
A. S. Ahamed, S. Devi, N. S. Rajessh et al.· Cureus· 0 citations
Background: Segmental Le Fort I osteotomy combined with interdental alveolar bone reduction is a technically challenging procedure, and the accuracy of patient-specific implants (PSIs) in this setting has not been well established. This study aimed to assess the three-dimensional (3D) repositioning accuracy and safety...
Xin-Yu Xu, Ling Wu, Zi-Li Li et al.· Journal of Clinical Medicine· 0 citations
Advancements in medical image acquisition facilitate patient-specific virtual surgical planning and surgical navigation in maxillofacial interventions such as Le Fort I osteotomy. Augmented reality (AR) allows superimposition of patient data onto the surgical field for guidance. The aim of this study was to develop and...
M. Benmahdjoub, B. Cornelissen, A. Thabit et al.· International Journal of Ora...· 0 citations
BACKGROUND
Syndromic hypoplasia of the midface can be addressed by Le Fort III osteotomy. Three-dimensional planning tools and cutting guides have the potential to facilitate the design of Le Fort III osteotomy and distraction vectors, anticipate potential challenges, and mitigate adverse events. This study aimed to ev...
H. Vercruysse, J. Rubio-Palau, E. van De Casteele et al.· The Journal of craniofacial...· 0 citations
Periapical lesions persisting after root canal treatment, particularly those radiographically suggestive of true cysts, often necessitate surgical management. This report introduces a synergistic technique for precise periapical surgery in anatomically challenging areas, combining a 3D-printed osteotomy guide with an u...
Jie-Ying Li, Hao-Yu Sun, Xiaoyang Shan et al.· Frontiers in Surgery· 0 citations
Cubitus varus is the most common long-term complication following supracondylar humeral fractures. Although traditional step-cut osteotomy yields reliable clinical outcomes, the intraoperative osteotomy direction and angle remain largely dependent on the surgeon's experience, resulting in suboptimal precision. Although...
Xiao-Fan Huang, Fu-Lin Tang, Jia-Lin Zhuang et al.· Frontiers in Surgery· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.