Skip to content
Open access

Development and Validation of an LC-MS/MS-Based Screening Method for Determination of Salbutamol in Urine for Doping Control Using a Surrogate Analyte Approach with Stable Isotope-Labeled Salbutamol (Salbutamol-d9)

Aug 2026 · Iranian journal of pharmaceutical research · Vol 25 · 0 citations · 26 references
Medicine

TL;DR

Findings indicate that this isotope-based surrogate analyte approach eliminates the need for calibration curves, compensates for matrix effects and sample preparation errors, and improves analytical reliability and efficiency across biological matrices.

Abstract

Background Athletic doping has long received attention in the sports community. Salbutamol is prohibited by the World Anti-Doping Agency (WADA) both in and out of competition, with a urinary concentration threshold of 1000 ng/mL defining the legal limit. Traditional liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical methods that use an internal standard cannot fully overcome matrix effects and biological variation, requiring revalidation for different biological samples; this process can be time-consuming and can remain prone to matrix-related errors. Objectives To develop a novel approach for screening salbutamol in urine that overcomes the limitations of traditional LC-MS/MS methods and improves analytical reliability and efficiency across biological matrices. Methods A surrogate analyte-based LC-MS/MS method was developed for the quantitative determination of salbutamol in human urine, using salbutamol-d9 as a stable isotope-labeled surrogate analyte. During method optimization, concentrations ranging from 1 ppm to 0.1 ppb were analyzed in aqueous and urine samples to evaluate extraction efficiency, purification, and matrix effects. Molar-equivalent concentrations of unlabeled salbutamol (1000 ng/mL, the WADA legal limit) and labeled salbutamol (1039 ng/mL) were analyzed in both matrices to validate the surrogate analyte approach and confirm comparable peak areas. To evaluate the applicability of the method, urine samples were collected from healthy volunteers after oral administration of 4 mg salbutamol. All samples were extracted under alkaline conditions using liquid–liquid extraction and analyzed by LC-MS/MS in positive-ion mode with multiple reaction monitoring (MRM). The labeled compound served as a reference for interpretation of the results. Method validation was performed according to international guidelines, including assessments of linearity, precision, accuracy, and sensitivity. Results The method demonstrated excellent linearity (R2 > 0.99), with intra- and inter-day precision within 8% RSD and acceptable accuracy. The limits of detection (LOD) and quantification (LOQ) were 0.3 and 1 ng/mL, respectively. Analysis of urine from healthy volunteers following a 4 mg oral dose confirmed reliable quantification for up to 24 hours, demonstrating applicability to biological matrices. Conclusions These findings indicate that this isotope-based surrogate analyte approach eliminates the need for calibration curves, compensates for matrix effects and sample preparation errors, and improves analytical reliability and efficiency across biological matrices.

Read PDF

Similar papers

Open access Oct 2026

Development and Validation of an In-House LC-MS/MS Method for the Qualitative and Quantitative Determination of 23 New Psychoactive Substances in Human Urine

The rapid diversification of new psychoactive substances (NPS) has generated a persistent analytical burden for forensic toxicology laboratories, particularly when biologically relevant concentrations are low, urinary matrices are complex, and the chemical life cycle of target compounds changes faster than routine labo...

Kemal Kural, Sevil Atasoy · 0 citations
Open access Aug 2026

Development and Validation of an LC–MS/MS Method for the Quantitative Determination of Vildagliptin in Analytical Standard Solutions Using Linagliptin as an Internal Standard

An LC–MS/MS procedure was developed and evaluated for measuring vildagliptin in analytical standard solutions, with linagliptin serving as the internal standard and the validation applies to prepared analytical solutions and does not establish performance in dosage forms or biological matrices.

Yıldırım Cesaretli, Burcu Eser, Esra Merve Zanbak Çotaoğlu et al. · 0 citations
Open access Sep 2026

SIL-IS LC-MS/MS method for rapid quantification of phloroglucinol in human plasma: development, validation and application to a pharmacokinetic study.

A sensitive, rapid, and robust liquid chromatography-tandem mass spectrometry method incorporating a stable isotope-labeled internal standard incorporating phloroglucinol-13C6 was developed and validated and successfully applied to a pharmacokinetic and bioequivalence study of phloroglucinol orally disintegrating table...

Qi-Qin Sun, Xiang-Hong Li, Yun-Jie Dong et al. · 0 citations
Sep 2026

An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of piperacillin in human serum and plasma

Abstract Objectives Piperacillin is a broad-spectrum antibiotic used to treat critically ill patients with severe infections, requiring therapeutic drug monitoring (TDM). We report the development of an isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure (RMP)...

Sandra Fleischer, J. Taibon, Neeraj Singh et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.