Aug 2026· Magnetic Resonance in Medical Sciences· Vol 25, pp. n/a· 1 citation· 51 references
Medicine
TL;DR
It is found that hyperintense signals in mice extend to arteries, major veins, and ventricular structures, different from human pCASL images, where hyperintense signals are predominantly present in arteries.
Abstract
Abstract Purpose Pseudo-continuous arterial spin labeling (pCASL) MRI is a widely used, noninvasive, contrast-agent-free technique for measuring cerebral blood flow (CBF) and assessing vascular dysfunction across diverse clinical settings and murine disease models. In practice, arterial-transit artifacts that generate hyperintense signal in CBF maps warrant careful consideration. While these effects are well characterized in humans, they are less well understood in mice owing to the marked interspecies physiological differences. Methods To address this knowledge gap, we systematically characterized pCASL hyperintense signal as a function of post-labeling delay (PLD) and crusher-gradient strength in mice. Numerical simulations were also performed to validate the experimental findings. Results We found that hyperintense signals in mice extend to arteries, major veins, and ventricular structures. Such a pattern was different from human pCASL images, where hyperintense signals are predominantly present in arteries. Statistical analyses supported a PLD of 500 milliseconds as a pragmatic balance between detection sensitivity and suppression of vascular contamination. Additional experiments and numerical simulations showed that, within the tested range, stronger crusher gradients provided little extra vascular suppression—primarily because large vessel calibers relative to small voxels limit intravoxel phase dispersion. Conclusion These findings refine the interpretation of murine pCASL signals and facilitate more accurate perfusion imaging in preclinical pathophysiological studies.
BACKGROUND
Combining the delays alternating with nutation for tailored excitation (DANTE) pulse with multi-delay arterial spin labeling (MD-ASL) enables arterial cerebral blood volume (CBVa) quantification. However, CBVa estimation may be compromised in moyamoya disease (MMD) because of prolonged arterial transit time...
Yuki Matta, Shota Ishida, M. Isozaki et al.· Journal of Neuroscience Meth...· 0 citations
These findings provide a normative 7 T semiquantitative benchmark and show distinct compartment-specific post-contrast temporal profiles together with inter-individual variability.
D. van Westen, Nelly Vuong, Erisa Elhyka et al.· Scientific Reports· 0 citations
PURPOSE
To develop and evaluate a single-acquisition integrated MRI sequence named SNAPFLOW for simultaneous assessment of intracranial arterial lumen morphology, vessel wall, and blood flow within a single acquisition.
METHODS
SNAPFLOW integrates Simultaneous Non-contrast Angiography and intraPlaque hemorrhage (SNAP...
Zi-Xuan Han, Shao-Kang Wen, Yong-Lin Chen et al.· Magnetic Resonance in Medici...· 0 citations
Purpose: Inter-scanner variability in cerebral blood flow (CBF) quantification limits reproducibility in multi-center arterial spin labeling (ASL) studies. We developed and validated a vendor-agnostic pseudo-continuous ASL (PCASL) sequence using the open-source Pulseq framework, and assessed its extensibility to advanc...
Jia-Ning Zhang, Jun Wang, Joseph G. Woods et al.· 0 citations
PURPOSE
To develop an efficient dynamic pseudo-continuous arterial spin labeling (pCASL) MRI technique for whole-brain microvascular flow pulsatility imaging.
METHODS
The proposed technique combines pCASL with a segmented stack-of-stars golden-angle radial acquisition. All collected k-space segments were retrospectiv...
Tian-Rui Zhao, Jia-Ning Tang, Yi-Ning He et al.· Magnetic Resonance in Medici...· 0 citations
Accurate quantification of apparent transverse relaxation (T2) in brain can be useful for non-invasive assessment of blood oxygenation and blood-brain barrier (BBB) function. While arterial spin labeling (ASL) combined with multi-echo readouts offers a contrast-agent-free approach to map apparent T2, in vivo applicat...
Jia-Wen Sun, C. Yuan, Jun Xu et al.· Imaging Neuroscience· 0 citations