Skip to content

Shear-Wave Elastography, Superb Microvascular Imaging, and B-mode US for Diagnostic Accuracy in Soft Tissue Tumors.

Aug 2026 · Radiology · Vol 320 2, pp. e250278 · 1 citation · 27 references
Medicine

TL;DR

SWE and SMI improved diagnostic accuracy in evaluating STTs, as measured by area under the curve (AUC), which was higher in nonbenign than in benign STTs.

Abstract

Background Differentiating benign from malignant soft tissue tumors (STTs) remains challenging, and conventional US alone is often insufficient. This study evaluated whether elastography and microvascular imaging improve diagnostic accuracy. Purpose To assess the ability of US techniques-B-mode US, shear-wave elastography (SWE), and superb microvascular imaging (SMI)-to discriminate benign from nonbenign STTs. Materials and Methods This tertiary referral center retrospective diagnostic accuracy study included consecutive patients with STTs referred for biopsy between February 2022 and July 2023. B-mode US features were recorded, including largest diameter (LD), deepest diameter (DD), DD-to-LD ratio, and SWE and SMI values. Histologic examination served as the reference standard. Receiver operating characteristic curves were used to evaluate predictions from single-variable and multivariable logistic regression models, including age and imaging-derived variables. The area under the curve (AUC) was used to summarize performance. Results A total of 167 lesions from 167 patients (mean age, 59.3 years ± 13.8 [SD]; 88 women) were included. Mean SWE and SMI values were higher in nonbenign than in benign STTs (SWE value, 4.00 m/sec vs 2.65 m/sec; SMI value, 31.5% vs 6.2%; both P < .001). DD and DD-to-LD ratio also differed between benign and nonbenign lesions (mean DD, 2.55 cm vs 4.57 cm; DD-to-LD ratio, 0.37 vs 0.51; both P < .001). Receiver operating characteristic analysis revealed AUCs of 0.82 (95% CI: 0.73, 0.92) for SMI and 0.75 (95% CI: 0.66, 0.85) for SWE. SMI sensitivity and specificity were 71% (22 of 31; 95% CI: 55, 87) and 87% (94 of 108; 95% CI: 81, 93), respectively; SWE sensitivity and specificity were 75% (24 of 32; 95% CI: 60, 90) and 71% (89 of 126; 95% CI: 63, 79). Combining LDs and DDs with SWE and SMI improved AUC to 0.87. Conclusion SWE and SMI improved diagnostic accuracy in evaluating STTs. © RSNA, 2026 Supplemental material is available for this article. See also the editorial by Lee and Stewart in this issue.

View source

Similar papers

Aug 2026

Automated Standardization of the Shear-wave Elastography Effective Region Using DeepLabV3 Improves Malignancy Assessment in Thyroid Nodules: A Single-institution Multicampus Study.

RATIONALE AND OBJECTIVES To assess whether a DeepLabV3-based model can standardize the shear-wave elastography (SWE) effective region in thyroid nodules and improve maximum Young's modulus (Emax)-based malignancy assessment. MATERIALS AND METHODS This retrospective single-institution multicampus study included 678 tr...

Lei Hu, Min Tang, Xiahui Ren et al. · 0 citations
Open access Oct 2026

Utility of shear-wave elastography in addition to ultrasonography in evaluation of thyroid nodules: Correlation with cyto-histopathological findings

Thyroid nodules are common clinical findings, and accurate prebiopsy characterization is essential as approximately 5%–15% harbor malignancy. This study evaluates the utility of shear-wave elastography (SWE) as an adjunct to conventional ultrasonography (USG) in differentiating benign from malignant thyroid nodules...

Somya Gupta, Gitanjali Satapathy, Sahil Gupta et al. · 0 citations
Aug 2026

Super-resolution Ultrasound Combined with Contrast-enhanced Ultrasound: An Exploratory Approach for Differentiating Benign From Malignant Renal Tumors Based on Microvascular Characteristics.

SRUS non-invasively reveals unique microvascular architecture and heterogeneity in renal malignancies, and the combined SRUS-CEUS approach shows promise for improving differential diagnostic accuracy.

Lu Zhang, Jie Tian, Yilai Chen et al. · 0 citations
Open access Sep 2026

Role of 2D shear wave elastography in differentiating malignancy from focal liver lesions as compared to multiphasic contrast enhanced computed tomography

Background: Liver cancer is the third most common cause of cancer mortality worldwide. A precise evaluation of benign and malignant liver lesions is very important for the patients.  In the present study, we aim to evaluate the use of SWE in the differentiation of malignant from benign focal liver lesions and to determ...

K. Senger, Rameez Akhand, K. Bhanu et al. · 0 citations
Open access 2026

Clinical value of shear wave elastography (SWE) combined with superb microvascular imaging (SMI) for the evaluation of semen abnormalities.

OBJECTIVE To investigate the clinical value of shear wave elastography (SWE) and superb microvascular imaging (SMI) in patients with semen abnormalities. METHODS A total of 150 patients with abnormal semen parameters who were treated at the Reproductive Center of the Affiliated Hospital of Putian University between J...

Hai-Lan Chen, Jian-Xin Huang, Wei Li et al. · 0 citations
Open access Jan 2026

Diagnostic and Monitoring Value of 2D Shear Wave Elastography in Subacute Thyroiditis: A Prospective Case–Control Study

Purpose This study aimed to analyze the applicability of different shear wave elastography (SWE) methods in the diagnosis, differentiation, and monitoring of subacute thyroiditis (SAT). Methods This prospective study included 26 patients diagnosed with SAT and 40 healthy controls. All participants underwent conventiona...

Ioana Golu, M. Balaș, Mervat Matei et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.