Both TICL and ICL are safe and effective for low myopic astigmatism and higher uncorrected visual acuity than ICL, but the nonrandomized design and selection bias necessitate caution in claiming comparative superiority.
Abstract
Background Implantable collamer lens (ICL) and toric ICL (TICL) have shown effectiveness for myopic and astigmatic patients. This study aims to compare the visual and refractive outcomes of TICL and ICL implantation for low myopic astigmatism. Methods This single-center, retrospective, non-consecutive, and non-randomized study included 124 eyes of 124 patients with low myopic astigmatism who underwent TICL or ICL implantation. Visual acuity, refractive outcomes, visual quality, and ocular parameters were assessed at baseline, 3 months, and 12 months postoperatively. The surgical results were reported using standard graphs and double-angle astigmatism vector analysis. Results Both groups demonstrated excellent safety (TICL: 1.28±0.18; ICL: 1.19±0.16) and efficacy (TICL: 1.21±0.19; ICL: 1.09±0.16), with high predictability for spherical equivalent refraction (R2 of 0.980 and 0.984, respectively) and stable refractive outcomes at 12 months. UDVA was marginally better in the TICL group (−0.08±0.07 vs −0.03±0.06, p<0.001). Crucially, TICL yielded significantly lower residual astigmatism (−0.16±0.28 D vs −0.33±0.40 D, p < 0.05) and a smaller prediction error on vector analysis. Despite these refractive differences, objective visual quality metrics improved significantly in both groups, with no statistically significant intergroup differences observed. Conclusions Both TICL and ICL are safe and effective for low myopic astigmatism (0.75–1.0 D). Although TICL yielded significantly lower residual astigmatism and higher uncorrected visual acuity than ICL, the nonrandomized design and selection bias necessitate caution in claiming comparative superiority. Toric correction for such low astigmatism should be individualized, integrating clinical benefits with economic and safety factors.
PURPOSE
To investigate the long-term visual outcomes of the Implantable Collamer Lens (ICL) with a central hole (ICL V4c; STAAR Surgical) in eyes with an anterior chamber depth (ACD) of 2.6 to 2.8 mm.
METHODS
This retrospective, non-comparative, interventional case series included 41 eyes of 41 patients receiving ICL...
Hong-Yu Kong, Ling-Ling Niu, Jun-Feng Li et al.· Journal of refractive surger...· 0 citations
SMILE Pro using the VISUMAX 800 femtosecond laser provides safe and predictable correction of myopic astigmatism with good axis alignment, however, the observed undercorrection in higher cylinders suggests that further optimization of astigmatic nomograms may improve refractive accuracy.
İ. İritaş, Z. Burke· International Journal of Oph...· 0 citations
In eyes with low corneal astigmatism, 1 D toric IOLs reduced postoperative refractive astigmatism, particularly in eyes with against-the-rule (ATR) astigmatism and at higher levels of baseline corneal astigmatism, but did not improve uncorrected or corrected visual acuity overall.
B. Connell, Jack X. Kane· Ophthalmology and Therapy· 0 citations
Objective
The objective of the study is to evaluate the visual and refractive outcomes of implantable Collamer lens (ICL) implantation with a new central port design.
Methods
This is a retrospective observational study of patients with myopia and myopic astigmatism who underwent procedures for the ICL (STAAR Surgical...
G. Vera-Duarte, N. Zatarain-Barrón, D. Jimenez-Collado et al.· Cirugía y Cirujanos· 0 citations
Purpose To evaluate 12-month visual and clinical outcomes after implantation of a monofocal aspheric hydrophobic acrylic intraocular lens (IOL) delivered with a preloaded system. Methods This investigator-initiated, prospective, single-center, uncontrolled feasibility study enrolled 30 patients undergoing unilateral or...
Oliver Hassel, M. K. Hallak, Max K Köppe et al.· Clinical Ophthalmology· 0 citations
PURPOSE
To determine the optimal myopic target refraction for enhanced monofocal IOL implantation in highly myopic cataract patients.
METHODS
A retrospective comparative study was conducted in Zhongshan Ophthalmic Center, China. Cataract patients with axial length (AL) ≥ 26 mm who underwent phacoemulsification with e...
Dan-Yue Chen, Hao-Wen Lin, Xiao-Hang Xie et al.· Graefe's archive for clinica...· 0 citations