Skip to content
Open access

Dual readout RT-LAMP for rapid on-site dengue virus detection and serotyping

Sep 2026 · Microbiology spectrum · Vol 14 · 0 citations · 39 references
Medicine

TL;DR

Four serotype-specific dengue virus (DENV) reverse transcription (RT)-LAMP assays are developed that work at a constant temperature without the need for sophisticated and expensive equipment, rendering the assays suitable for point-of-care applications in dengue-endemic regions worldwide.

Abstract

ABSTRACT Dengue is the fastest-growing mosquito-borne disease, with over 14 million reported cases globally in 2024, rendering dengue a major public health issue of global concern. Fast and reliable serotype-specific diagnosis of dengue is critical for patient risk management and epidemiological surveillance. While real-time PCR currently remains the gold standard for dengue virus detection, it requires thermal cyclers and trained personnel in an established laboratory infrastructure, limiting its use in low-resource settings. Loop-mediated isothermal amplification (LAMP) offers a promising alternative, yet currently available reverse transcription assays for dengue either rely on limited sequences used for primer design, thus failing to adequately capture global genetic diversity, or use multiple primer sets, increasing complexity and costs. We developed four serotype-specific dengue virus (DENV) reverse transcription (RT)-LAMP assays in which primer design was informed by 4,277 whole-genome sequences from different geographical regions. Degenerate base positions were incorporated into primers to achieve broad detection capability while minimizing the number of distinct oligonucleotides needed. The assays achieved analytical sensitivities of 96–734 genome equivalents per reaction after 60 min. Clinical evaluation using 95 PCR-confirmed positive samples from Sri Lanka, including serotypes 1–3, demonstrated detection rates of 91.2% for DENV1, 78.6% for DENV2, and 100% for DENV3, with no cross-reactivity observed between serotypes. Evaluation using DENV4-spiked serum demonstrated reliable detection at clinically relevant viral loads, with complete detection at quantification cycle (Cq) values of ~30. A dual readout design enables both real-time fluorescence detection and equipment-free visual colorimetric detection, rendering the assays suitable for point-of-care applications in dengue-endemic regions worldwide. IMPORTANCE Dengue virus infections pose a growing threat to global health, with cases doubling annually since 2021, yet reliable diagnostic tools remain inaccessible in many affected regions. Current gold-standard molecular tests require expensive equipment and specialized laboratories, creating a critical gap in dengue-endemic areas where rapid, on-site diagnosis could save lives through early patient management and outbreak control. This study addresses this gap by developing dengue virus serotype-specific detection assays that work at a constant temperature without the need for sophisticated and expensive equipment. By analyzing thousands of dengue virus genome sequences and strategically incorporating degenerate bases, we designed primers that can detect diverse viral strains while maintaining simplicity and low cost. The assays provide results in 40–60 min, depending on the workflow, and can be read visually without instruments, making them practical for use in clinics, field settings, and resource-limited laboratories where dengue burden is highest. Dengue virus infections pose a growing threat to global health, with cases doubling annually since 2021, yet reliable diagnostic tools remain inaccessible in many affected regions. Current gold-standard molecular tests require expensive equipment and specialized laboratories, creating a critical gap in dengue-endemic areas where rapid, on-site diagnosis could save lives through early patient management and outbreak control. This study addresses this gap by developing dengue virus serotype-specific detection assays that work at a constant temperature without the need for sophisticated and expensive equipment. By analyzing thousands of dengue virus genome sequences and strategically incorporating degenerate bases, we designed primers that can detect diverse viral strains while maintaining simplicity and low cost. The assays provide results in 40–60 min, depending on the workflow, and can be read visually without instruments, making them practical for use in clinics, field settings, and resource-limited laboratories where dengue burden is highest.

Read PDF

Similar papers

Oct 2026

A-073 Validation of a Qualitative PCR for Dengue Virus Detection and Serotyping

Dengue is a mosquito-borne viral infection caused by four distinct serotypes: dengue virus 1, 2, 3, and 4 (DENV 1-4). Globally, dengue affects up to 400 million individuals each year and infection can occur multiple times throughout a person’s lifetime. Disease severity varies by the infecting serotype and is oft...

Alex Hall, Tien Le, Thomas J. Urban et al. · 0 citations
Open access Sep 2026

Comprehensive conservation profiling enables a robust multiplex RT-qPCR assay for simultaneous pan-detection and serotype discrimination of dengue virus

A novel multiplex real-time RT-qPCR assay enabling simultaneous pan-DENV detection and serotype identification in two tubes, comprising six reactions including an internal control (IC), thereby streamlining dengue diagnosis and enhances the molecular understanding of DENV fragments in clinical specimens.

Bo-Han Xu, Dong-yan Xiong, Jin-Zhang Wang et al. · 0 citations
Sep 2026

A two-step RT-LAMP workflow combining colorimetric screening and lateral flow assay for rapid differentiation of SARS-CoV-2 and influenza A.

Several infectious diseases share overlapping clinical symptoms and transmission routes despite being caused by distinct pathogens. Consequently, diagnostic tests capable of differentiating these infections are crucial for minimizing clinical and epidemiological misdiagnoses. However, the simultaneous detection and dis...

L. Ferreira, P. F. Estrela, P. Resende et al. · 0 citations

Protocol for Detecting and Sequencing Chikungunya Virus from Field-Collected Mosquitoes.

This protocol includes mosquito homogenization using a bead-based mechanical disruptor, RNA extraction using TRIzol reagent with minor modifications, molecular screening using CHIKV-specific RT-qPCR, and whole-genome amplification followed by sequencing on Illumina platforms.

C. Banho, Olivia Borghi Nascimento, Lívia Sacchetto et al. · 0 citations
Open access Oct 2026

Detection of Influenza D Virus using Reverse Transcription Loop-Mediated Isothermal Amplification

The Orthomyxoviridae family includes influenza D virus (IDV), an emerging pathogen primarily affecting cattle and swine; there is evidence of cross-species transmission and potential zoonotic risk. Although active human infections have yet to be confirmed, high seroprevalence in cattle-exposed populations highlights th...

Carlos Abelardo dos Santos, Jia-Lu Li, P. V. van Diemen et al. · 0 citations
Sep 2026

Ultra-rapid reverse transcription-free exponential amplification reaction (RTF-EXPAR) technology for hepatitis A virus detection

Hepatitis A virus (HAV) poses severe food safety threats, yet conventional detection methods suffer from low sensitivity or complex operation. This study established a reverse transcription-free exponential amplification (RTF-EXPAR) coupled with Single-strip nucleic acid test strip for rapid HAV RNA detection. The...

Y. Bai, J. Zheng, J. Zhang et al. · 0 citations