Skip to content
Review Open access

Timing, frequency, and glycaemic target values for self-monitoring in adults with type 1 diabetes mellitus.

Aug 2026 · Cochrane Database of Systematic Reviews · Vol 8, pp. CD016263 · 0 citations · 63 references
Medicine

TL;DR

Overall, more frequent self-monitoring may be associated with lower haemoglobin A1c levels, although the evidence is very uncertain.

Abstract

Rationale

Evidence guiding how often adults with type 1 diabetes mellitus should self-monitor blood glucose, when to monitor, and which glycaemic targets to use is limited and inconsistent. The available research has not clearly linked different self-monitoring strategies to meaningful clinical outcomes, and evidence is particularly scarce for low-resource settings. Clarifying these uncertainties is important to support informed decision-making and equitable diabetes care worldwide.

Objectives

To assess the effects of different timing, frequency, and glycaemic target values for self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes mellitus. SEARCH

Methods

We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Science Citation Index Expanded and Emerging Sources Citation Index (Web of Science), ClinicalTrials.gov, and the WHO ICTRP, without language restrictions. The date of the last search across all databases was 7 January 2026. ELIGIBILITY CRITERIA We included randomised controlled trials and eligible non-randomised comparative studies with a minimum duration of 24 weeks that evaluated different timing, frequency, or glycaemic target values for SMBG in adults with type 1 diabetes mellitus. We excluded cross-over and cluster-randomised trials, modelling studies, studies of pregnant individuals, and studies focused solely on self-monitoring in the context of insulin pump use. OUTCOMES Our critical outcomes were glycaemic control (haemoglobin A1c and fasting blood glucose), hypoglycaemia (mild or moderate, severe, and nocturnal), diabetic ketoacidosis, microvascular and macrovascular complications, and quality of life. RISK OF BIAS We assessed the risk of bias in included studies using the Cochrane RoB 2 tool for randomised controlled trials and the ROBINS-I tool for non-randomised comparative studies. SYNTHESIS

Methods

We did not conduct a meta-analysis, as effect measures and outcome reporting varied across the included studies and only three studies met the eligibility criteria. Instead, we followed Cochrane guidance on Synthesis Without Meta-analysis (SWiM) and summarised findings through structured tabulation of study characteristics and results, complemented by visual presentation of individual study effect estimates without statistical pooling. We did not use vote counting based on statistical significance. We assessed the certainty of the evidence using GRADE. INCLUDED STUDIES We included three studies conducted in Europe and North America, involving a total of 16,481 adults with type 1 diabetes mellitus. One study was a randomised controlled trial, and two studies were observational comparative studies. All studies evaluated the frequency of SMBG; none reported eligible data on timing or glycaemic target values. Follow-up durations ranged from 9 to 24 months. SYNTHESIS OF

Results

Timing of SMBG No eligible studies investigating the timing of SMBG were identified. Frequency of SMBG Three studies involving a total of 16,481 adults investigated the frequency of SMBG in adults with type 1 diabetes mellitus. Overall, more frequent self-monitoring may be associated with lower haemoglobin A1c levels, although the evidence is very uncertain. In the randomised controlled trial (123 participants), the mean change in haemoglobin A1c at nine months was -0.43% in the intervention group compared with +0.23% in the control group, corresponding to approximately 0.7% lower haemoglobin A1c with more structured and frequent monitoring (mean difference (MD) -0.66, 95% confidence interval (CI) -0.94 to -0.38). The certainty of the evidence for this outcome was very low. In one observational study (1159 participants), adherence to self-monitoring guidelines may be associated with a 1.0% lower adjusted mean haemoglobin A1c (MD -1.00, 95% CI -1.21 to -0.79) compared with non-adherence. The third study (15,199 participants) reported lower haemoglobin A1c values with increasing monitoring frequency (P < 0.001), with the lowest values among those monitoring more than six times per day. Across both studies, the certainty of the evidence was very low. No included study reported effects on hypoglycaemia, diabetic ketoacidosis, microvascular or macrovascular complications, or quality of life. Glycaemic target values for SMBG No eligible studies investigating glycaemic target values for SMBG were identified. AUTHORS'

Conclusions

No studies evaluated different timings of self-monitoring or different glycaemic target values. Three studies (one randomised controlled trial and two observational studies) assessed the frequency of self-monitoring and haemoglobin A1c. More frequent self-monitoring may be associated with lower haemoglobin A1c, although the evidence is sparse, frequency categories were inconsistent across studies, and the included studies had methodological limitations. The certainty of the evidence was very low for all outcomes, driven by risk of bias, imprecision, and inconsistency across studies. No studies reported hypoglycaemia, diabetic ketoacidosis, quality of life, or other critical outcomes. The evidence is insufficient to draw any firm conclusions about the effects of different self-monitoring strategies in adults with type 1 diabetes mellitus.

Funding

This review was funded by the World Health Organization through an Agreement for Performance of Work (APW 203512799). REGISTRATION The review was registered in PROSPERO (CRD42025639736) in February 2025.

Read PDF

Similar papers

Review Open access Aug 2026

Conflicting evidence for continuous glucose monitoring in gestational diabetes: current challenges and the imperative for individual participant data meta-analysis

The incidence of gestational diabetes mellitus (GDM) is rising along with rates of obesity and type 2 diabetes. GDM is associated with an increased risk of various short- and long-term complications for both mother and child, including type 2 diabetes. Managing GDM requires a multidisciplinary approach that includes di...

Ina Geerts, Catherine H. Yu, Nina Embo et al. · 0 citations
Review Sep 2026

Optimizing Continuous Glucose Monitoring for Older Adults with Diabetes: From Clinical Evidence to a Practical Implementation Pathway.

A pragmatic geriatric CGM pathway with an explicit triage algorithm is proposed that emphasizes risk-based candidate selection, functional assessment, tailored device and support models, individualized alerts and glycemic goals, focused review of CGM metrics, structured education, and early follow-up.

Tong Yang, Jinghao Cai, Jiaying Ni et al. · 0 citations
Review Sep 2026

Continuous Glucose Monitoring in Type 1 Diabetes: Evidence for Glycemic Control and Quality of Life Gains

Type 1 diabetes mellitus was characterized by absolute insulin deficiency, marked glycemic excursions, and vulnerability to hypoglycemia, particularly during sleep, exercise, and intercurrent illness. Conventional capillary testing offered episodic measurements that incompletely captured glycemic variability, thereby l...

Mutebi Mark · 0 citations
Review Open access Aug 2026

Early insulin initiation in type 2 diabetes: efficacy, safety, and clinical implications: a systematic review with narrative synthesis

Aims/background Early insulin initiation in type 2 diabetes mellitus (T2DM) is proposed to improve glycemic control, preserve β-cell function, and potentially reduce long-term complications. Evidence suggests that starting insulin within five years of diagnosis may offer additional metabolic benefits, but its clinical...

Osama B. Albasheer, Amal H. Mohamed, Nagla Abdalghani et al. · 0 citations
Open access Sep 2026

Current Diabetes Self-Management and the Number of Documented Complications in Adults with Type 2 Diabetes: A Cross-Sectional Study

Background and Objectives: Current self-management behavior may not reflect the long-term exposures that led to established complications in people with type 2 diabetes (T2D). To assess whether Diabetes Self-Management Questionnaire (DSMQ) scores were associated with the number of documented diabetes-related and cardio...

Paula-Alexandra Popovici, Andreea Igna, Bianca-Lăcrimioara Petca et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.