Assessing angular and linear misfits in zirconia frameworks through torque/time graph interpretation: A proof of concept.

Sep 2026 · Journal of Prosthodontics · 0 citations · 21 references
Medicine

TL;DR

Within the limitations of this in vitro, proof-of-concept study, interpreting torque/time graphs obtained during prosthetic screw insertion may represent a promising non-invasive approach to detect misfits in zirconia complete-arch frameworks.

Abstract

Purpose

Passive fit in implant-supported complete-arch prostheses is the key to long-term success. The aim of this in vitro, proof-of-concept study was to examine whether torque/time graphs generated from a surgical motor during the prosthetic screw insertion process show consistent patterns of digitally controlled angular and linear misfits in monolithic zirconia frameworks.

Materials And Methods

Eight high-strength, low-translucency zirconia blocks, suitable for complete-arch prosthetic frameworks, were manufactured and assessed. A standardized edentulous model with three implants was used. The two outer prosthetic screws were screwed and secured, whereas the central screw was tightened using a surgical motor, allowing real-time acquisition of torque/time graphs for each framework. Framework design was intentionally modified to introduce controlled degrees of angular and linear misfit. The resulting torque/time curves were analyzed to identify graphical patterns associated with each specific level of angular and linear misfit.

Results

Torque/time graphs were recorded for all zirconia frameworks. The control sample showed a gradual rise in torque to 13.7 N cm with a stable 5 revolutions per minute (rpm), indicating optimal passive fit. Frameworks with small linear (≤80 µm) or angular (≤1.9°) discrepancies displayed similar, clinically acceptable patterns. Linear misfits beyond 120 µm resulted in delayed torque progression and higher resistance, whereas at 160 µm, screw engagement failed, with torque plateau at 2.0 N cm. Angular misfits greater than 2.9° resulted in irregular torque curves and early mechanical tension. Deviations of 3.8° produced unstable torque, reduced rpm, and incomplete screw seating. At 4.8°, no engagement of the screw occurred, with torque values less than 2.0 N cm.

Conclusions

Within the limitations of this in vitro, proof-of-concept study, interpreting torque/time graphs obtained during prosthetic screw insertion may represent a promising non-invasive approach to detect misfits in zirconia complete-arch frameworks. This suggests a feasible approach to improve the objectivity of passive fit assessment in clinical practice, although further validation, both in vitro and in vivo, is recommended.

Read PDF

Similar papers

Open access Aug 2026

The effect of build angle and intraarch connector design on the accuracy and fit of additively manufactured complete-arch implant-supported interim fixed prostheses.

Within the limitations of this single-system in vitro study, AM complete-arch implant-supported interim fixed prostheses in a 0° no-bar configuration demonstrated accuracy comparable to SM HIPC, but the marginal gaps found in some groups were beyond clinical acceptability.

Steven Sonderegger, Pedro Molinero Mourelle, Manuel Aeschbacher et al. · 0 citations
Aug 2026

Screw Loosening and Torque Loss of Zirconia-Based Implant- Supported Dental Prostheses: A Retrospective Clinical Study.

PURPOSE Dental implants are a widely used and effective method for tooth replacement, yet complications such as abutment screw loosening remain a challenge. The aim of this study was to investigate the effect of different abutments, connection types and restoration types on abutment screw loosening. MATERIALS AND MET...

Saman Savabi, F. Nejatidanesh, G. Savabi et al. · 0 citations
Open access Sep 2026

Effect of Tightening Protocol on Reverse Torque and Plastic Deformation of Dynamic and Conventional Titanium Abutment Screws

Preload loss and plastic deformation of titanium abutment screws under repeated tightening are clinically significant yet incompletely characterized across systems with differing head geometries and surface treatments. Two ISO 14801-certified titanium screws were evaluated: hexalobular-head gold-plated (Gold-Tite®; 3i...

R. Batista, A. Moreira, Ru-Ben B. Rui et al. · 0 citations
Aug 2026

In Vivo Assessment of Complete-Arch Implant Impressions Using a Clinical Seating Score: A Proof-of-Principle Case Report.

The CSS may potentially provide a simple and standardized chairside method for evaluating the passive seating of complete-arch implant frameworks and help clinicians identify clinically relevant misfits before delivery of the definitive prosthesis and support more predictable decision-making during framework verificati...

Francesco Mintrone, F. Ferri, Rostyslav Havryltsiv et al. · 0 citations
Open access Aug 2026

ILLUSTRATIVE DATA VERSION — NOT FOR SUBMISSION Accuracy and Passive Fit of Digital versus Conventional Impression Techniques for Full-Arch Implant-Supported Prostheses: A Comparative In Vitro Study

In this illustrative dataset, digital impressions demonstrated lower RMS, linear, and angular deviations relative to the reference model compared with conventional impressions, suggesting a trend towards higher overall accuracy for the digital workflow.

Mahmoud abdoulGawy, Adel Ahmed · 0 citations
Open access Aug 2026

Effect of Angulated Screw Channel (ASC) design on the fracture resistance of implant-supported monolithic zirconia and lithium disilicate crowns: an in vitro study

Ti-base abutments with angulated screw channel (ASC) designs have been developed to address the esthetic challenges associated with labial screw access in anterior implant-supported single crowns, as well as the ergonomic limitations caused by restricted mouth opening in posterior crowns. Despite their increasing clini...

Bedia Gökten Uçar, Özlem Çölgeçen · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.