3D-printed titanium abutments demonstrated significantly greater mechanical stability than CAD-CAM-milled abutments, approaching the performance of the gold-standard prefabricated abutments, and prefabricated abutments demonstrated the highest reverse torque values after cyclic loading.
Abstract
Screw loosening and implant-abutment interface (IAI) are critical for the long-term success of implant-supported restorations. This study aimed to evaluate the effect of abutment manufacturing technique on reverse torque values and micro-gap measurements at the implant-abutment interface. Thirty dental implant-abutment-crown complexes (Implance, Verdent, Turkey) were randomly allocated into three groups (n = 10 each) based on the abutment manufacturing technique: Group I—prefabricated titanium abutments (manufacturer-supplied, Implance, Verdent, Turkey; titanium grade 5); Group II—CAD-CAM-milled titanium abutments; Group III—3D-printed titanium abutments (Selective Laser Melting, SLM). All abutments featured an internal hexagonal connection with platform switching. All crown abutments were tightened to 25 Ncm and subjected to cyclic loading (100 N, 1.6 Hz, 250,000 cycles). Removal torque was measured before and after loading. Micro-gaps at the implant-abutment and abutment-screw interfaces were evaluated using scanning electron microscopy (SEM). Statistical analysis was performed using One-Way ANOVA with Tukey’s Post Hoc test for reverse torque and the Kruskal-Wallis test for gap measurements (α = 0.05). After cyclic loading, the 3D-printed (SLM) abutments exhibited significantly higher reverse torque values (11.08 ± 0.11 Ncm) compared to CAD-CAM-milled abutments (6.40 ± 0.79 Ncm) (P < 0.001). Prefabricated abutments demonstrated the highest post-loading torque values (13.31 ± 0.31 Ncm). All intragroup comparisons showed statistically significant reductions from baseline (P < 0.0001). No significant difference was found in implant-abutment interface gaps among groups (P = 0.105). Within the limitations of this study, prefabricated abutments demonstrated the highest reverse torque values after cyclic loading. 3D-printed abutments showed significantly greater resistance to torque loss compared to CAD-CAM-milled abutments, approaching the performance of prefabricated abutments. The implant-abutment fit was comparable across groups, suggesting that connection design may be more influential than manufacturing method for macroscopic fit. 3D-printed titanium abutments demonstrated significantly greater mechanical stability than CAD-CAM-milled abutments, approaching the performance of the gold-standard prefabricated abutments. This suggests that additive manufacturing may offer a clinically viable alternative to milling when both customization and mechanical integrity are required. However, clinical studies are needed to confirm these in vitro findings.
Aim and Objective: Implant abutment microgap being one of the major problem leading to screw loosenings. The aim of this study was to evaluate the effect of chitosan-based sealant on the implant abutment interface by evaluating the abutment screw torque loss.Materials and Methods: CH/GP (chitosan β glycerophosphate) hy...
Purpose: This study investigated the surface morphology and roughness of the dental implant platform and abutment at their junction interface, comparing parameters before and after mechanical assembly (screwing). Methods: The experimental specimens comprised 40 implants from the TBR, Bone Level M System (TBR, France) w...
Teodora Filipova, S. Peev, Stanislav Mitkov· Dental journal· 0 citations
The manufacturing method of the zirconia abutments (3D-printing or milling) did not influence the fatigue behavior of the restorations, but the presence of a screw access hole in the abutments significantly reduced the fatigue behavior of the specimen.
Fernanda Cocco, Kétlin Fagundes Teixeira, N. de Freitas Daudt et al.· Odontology : official journa...· 0 citations
Preload loss is intrinsic to abutment screw tightening irrespective of design; RTV behaviour under repeated cycling is system-dependent, and abutment screws should be treated as limited-use components.
R. Batista, A. Moreira, Ru-Ben B. Rui et al.· Bioengineering· 0 citations
Evidence regarding tantalum nitride (TaN)-coated gold abutment screws is lacking, and studies on diamond-like carbon (DLC)-coated and anaerobic adhesive-coated abutment screws remain limited. This study evaluated the reverse torque values (RTVs) of abutment screws with different surface modifications. Sixty abutment sc...
Merve Dede, Ozgun Yusuf Ozyilmaz, Ozge Doganay-Ozyilmaz et al.· Journal of Functional Biomat...· 0 citations
Within the limitations of this single-system in vitro study, AM complete-arch implant-supported interim fixed prostheses in a 0° no-bar configuration demonstrated accuracy comparable to SM HIPC, but the marginal gaps found in some groups were beyond clinical acceptability.
Steven Sonderegger, Pedro Molinero Mourelle, Manuel Aeschbacher et al.· E -journal of dentistry· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.