Skip to content
Preprint

Scalable photoacoustic tomography implementations accounting for the spatial impulse response of transducers

Sep 2026 · 0 citations
Engineering

Abstract

Iterative model-based reconstruction in photoacoustic tomography repeatedly applies the forward operator mapping the initial pressure to the transducer signals, and its adjoint. At the scale of current three-dimensional systems, this operator cannot be stored and must be evaluated matrix-free, while accounting for the finite, focused surface of the transducers, whose spatial impulse response degrades the resolution when ignored. Representing the initial pressure by compactly supported radial functions, we show that the measured signal is exactly a temporal convolution between a system kernel gathering the radial function and the electrical impulse response, and a purely geometric quantity accounting for the portion of the transducer surface reached by the wave emitted from a voxel during one time step. Two implementations are proposed, differing only in how this quantity is evaluated: a quadrature over points of the surface, as in existing works, or a closed-form area, which never discretizes the surface. We derive closed forms for planar and cylindrically focused transducers and provide, in the latter case, two accelerations of the resulting elliptic integrals, a lookup table and a trapezoidal approximation, together with the piecewise planar approximation customary in the literature. These implementations reduce the per-voxel geometric computations and are released as an open-source Python package for graphics processing units. The performance of these operators is first demonstrated on a synthetic phantom, where the lookup-table-based operator reaches the accuracy of the exact evaluation ten times faster and outperforms the point discretization on both accuracy and runtime. A second experiment shows that they enable the processing of a realistic vascular phantom at full scale, with a higher peak signalto-noise ratio and a better resolution than the back-projection counterpart. The released implementations are an important step towards the adoption of three-dimensional modelbased photoacoustic reconstructions with finite and focused transducers.

View source

Similar papers

Preprint Aug 2026

On the Fundamental Limits of Single-snapshot Compressive Ultrasound Imaging Using Random Aberrative Masks

Compressive sensing emerges as a paradigm shift to realize real-time volumetric ultrasound imaging using a single element transducer equipped with an aberrative mask. Such a coded aperture encodes each scatterer in the FoV as a specific echo signal, compressing each volumetric into a time sequence that are reconstructe...

Zehua Dou, Yaokuan Zhang, Jialong Zhang et al. · 0 citations
Preprint Sep 2026

Dirichlet Splatting: Differentiable Rendering for Wave-Based Inverse Problems

Wave-based coherent imaging, including terahertz tomography, synthetic-aperture acoustics, and millimeter-wave radar, forms images by Fourier-processing finite-length signals, with an exact point spread function that is not Gaussian but a Dirichlet kernel: complex-valued, oscillatory, and periodic. However, transplanti...

Xing-Yu Chen, Wu-Qiong Zhao, Xin-Yu Zhang et al. · 0 citations
Preprint Aug 2026

PAGS: Autofocusing Photoacoustic Tomography via Speed-of-Sound-Adaptive Gaussian Splatting

PAGS, a differentiable framework for blind autofocusing PACT via speed-of-sound-adaptive Gaussian splatting, is proposed, which demonstrates improved reconstruction sharpness under heterogeneous acoustic media, robustness to sparse-view sampling, and computational benefits from the analytic Gaussian projection.

Jia Ge, Jin-Tao Ma, Bangxu Fan et al. · 0 citations
Preprint Aug 2026

The vanishing distance: a practical range boundary for dynamic wavefront shaping

Wavefront shaping (WFS) is a powerful modern method to control light propagation through scattering media, with applications ranging from biomedical imaging via cryptography to free-space optical communication. While WFS has been highly successful in static or slowly evolving media, its practical relevance in dynamic a...

Hugo Lassiette, Léa Testé, L. Krafft et al. · 0 citations
Open access Sep 2026

Density reconstruction from multi-directional quantitative Schlieren imaging using Poisson formulation

This study introduces a framework for reconstructing steady effective line-of-sight-averaged density fields in compressible flows using multi-directional quantitative Schlieren imaging. The experimental setup utilizes a quantitatively calibrated monochrome weak-lens Schlieren configuration to acquire directional densit...

Acar Celik, B. Cukurel · 0 citations
Open access Sep 2026

Clutter-Aware Reconstruction for Monostatic Ultrasound Acquisition: Application to Civil-Infrastructure Concrete NDE

Ultrasonic pulse-echo imaging is one of the most widely used non-destructive evaluation (NDE) modalities for monitoring the structural integrity of reinforced-concrete civil infrastructure such as bridge decks, tunnel linings, and dam walls. In this acquisition geometry, a single low-frequency transducer is mechanicall...

Abdulrahman M. Alanazi · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.