Skip to content
Open access

Comparative CFD Analysis of Double-Skin Façade Cavities Under Extreme Hot-Arid Conditions

Aug 2026 · Buildings · 0 citations · 33 references

Abstract

Double-skin façades (DSFs) can moderate heat transfer and airflow between the outdoor environment and the building interior; however, their performance in hot-arid climates is highly dependent on cavity geometry, ventilation arrangement, and the interaction between the airflow and any active cooling surfaces. The objective of this study is to establish, under a single idealised extreme hot-arid design point, how sealed, ventilated and actively cooled double-skin façade cavities differ in their predicted temperature, velocity and turbulent kinetic energy fields, and which arrangements merit controlled follow-up study. The four configurations are treated as an idealised comparative case study rather than as validated building-performance predictions. This exploratory study uses computational fluid dynamics (CFD) to compare the aerothermal behaviour of four DSF cavity configurations under prescribed external air and outer-wall temperatures of 50 °C, an inner-wall temperature of 24 °C, and an external inlet velocity of 3.06 m/s. The configurations comprise a sealed 0.4 m cavity (M1), a wind-driven ventilated 0.4 m cavity (M2), the same ventilated cavity with six 25 mm cooling pipes at 10 °C (M3), and a concept-stage lateral-flow arrangement combining a 0.10 m cavity, a 0.025 m slit and four 80 mm cooling pipes at 10 °C (M4). The simulations employ the standard k-ε turbulence model with fixed thermal boundary conditions. Along the reported sampling lines, M1 exhibited a nearly uniform air temperature of approximately 45.7 °C, whereas M2 remained close to the imposed 50 °C external-air temperature. M3 produced lower temperatures in the immediate vicinity of the cooling pipes, but most of the sampled profile remained near ambient conditions. M4 exhibited a broader spanwise temperature range of approximately 26.9–50 °C, with local pipe-adjacent air temperatures approaching 24 °C and cooler regions developing along parts of the lateral flow path. The findings provide preliminary concept-screening evidence and support further controlled parametric analysis, higher-fidelity modelling, and experimental validation.

Read PDF

Similar papers

Aug 2026

Influence of blind size on heat transfer and natural ventilation in double‐skin façades: A CFD study

The thermal performance of double‐skin façades (DSFs) is strongly affected by the design of shading devices integrated within the cavity. While previous studies have mainly focused on blind angle and position, the influence of blind slat size remains insufficiently explored, particularly under hot climate conditions. I...

Maha Fguiri, Ali Fguiri, M. Jeday et al. · 0 citations
Conference Jul 2026

Optimization Analysis of Thermal Distribution in a Confined Balcony Space Under Air-Conditioning Outdoor Unit Operation Using Taguchi-Based CFD Simulation

This study analyzes the thermal behavior and airflow characteristics within a confined balcony space under typical hot and humid climatic conditions in Ho Chi Minh City. A computational fluid dynamics (CFD) model was developed and numerically assessed through mesh-independence and convergence analyses, incorporating an...

Hung-Son Dang, Thi-Anh-Tuyet Nguyen, H. Lai · 0 citations
Open access Aug 2026

CFD-Based Simulation and Optimization of Summer Environmental Conditions in Laying Hen Houses

To address uneven temperature and relative humidity distributions, localized heat accumulation, and insufficient air velocity in an enclosed stacked-cage laying hen house, a three-dimensional computational fluid dynamics (CFD) model of the laying hen house was developed using field-measured structural and environmental...

Lili Zhang, Shan-Jie Zhang, Miaomiao Xie et al. · 0 citations
Open access Aug 2026

Season-Wise Three-Dimensional CFD Modelling of a Natural Evaporative Water Cooler: Development, Calibration and Experimental Validation

Natural evaporative water coolers provide refrigerant-free, ultra-low-energy water cooling for hot–dry climates, yet computational fluid dynamics (CFD) studies of such systems at full device scale are absent from the literature. This paper develops a three-dimensional CFD model of a complete natural evaporative water c...

M. Trivedi, Diptesh R. Patel · 0 citations
Open access 2026

Optimizing Hollow Block Roof Design: A Numerical Investigation of Coupled Heat Transfer under Solar Radiation

: The complex interplay of heat transfer mechanisms, namely conduction, natural convection, and radiation, within hollow block roofs exposed to solar irradiation gives rise to an inherently nonlinear thermal exchange problem. A key yet insufficiently explored question is the extent to which this nonlinearity governs th...

Ayoube Baalla, M. Najjaoui, T. Ait-Taleb et al. · 0 citations
Open access Aug 2026

CFD-based thermal-hydraulic analysis of double-pipe heat exchangers equipped with structured metal-foam inserts

Increasing heat transfer in double-pipe heat exchangers (DPHEs) is an interesting topic due to challenges that still remain to be solved, especially when working under low-to-moderate flow rate regimes where poor mixing and thermal boundary layers reduce the effectiveness of convection. Despite numerous studies conduct...

Inas Faiz Kadhim, Abbas J. Jubear Al-Jassani, H. Al-Bugharbee · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.