Aug 2026· The Journal of craniofacial surgery (Print)· 0 citations· 23 references
Medicine
TL;DR
Graft-augmented fixation significantly enhances biomechanical stability following mandibular advancement of BSSO and has the potential to decrease the risk of permanent lower border defects in larger advancement cases.
Abstract
Background
The success of bilateral sagittal split osteotomy (BSSO) depends on fixation stability, particularly in large mandibular advancements where conventional fixation methods may be insufficient and associated with lower border defects. Therefore, this study aimed to assess the stability of a graft-augmented fixation technique compared with conventional fixation methods for securing mandibular segments following the advancement of BSSO in cadaveric human mandibles.
Materials And Methods
Forty human hemimandibles underwent standardized sagittal split osteotomy with a 10 mm advancement and were stabilized using 3 bicortical screws, a single titanium plate with 4 screws, double titanium plates with 4 screws, or an allograft bone block combined with a single plate and 4 screws (experimental group). Nonoperated mandibles served as controls. The specimens were subjected to 3-point bending tests to evaluate their maximum load, flexural stress, load at maximum displacement, and modulus of elasticity.
Results
The graft-augmented fixation demonstrated a significantly higher mean maximum load (928±414 N) compared with three-screw fixation (331.5±131 N), single-plate fixation (389.9±144 N), double-plate fixation (490±173 N), and controls (310±15 N). Flexural stress was also markedly higher in the grafted group (P<0.002).
Conclusion
Graft-augmented fixation significantly enhances biomechanical stability following mandibular advancement of BSSO and has the potential to decrease the risk of permanent lower border defects in larger advancement cases.
Pedicle screw fixation is widely used in spinal surgery to achieve mechanical stability. However, in osteoporotic bone, reduced bone mineral density compromises screw anchorage, increasing the risk of loosening and failure. The main objective of the study was to compare the biomechanical performance, including pu...
Pavan Kumar Manjappa, Toppanahalli Venkatesh Ravi Kumar, Mahesh Manjunath· Indian Spine Journal· 0 citations
Aims To biomechanically compare the stability of mini-plate and dual-screw fixation following minimally invasive distal metatarsal osteotomy for hallux valgus, with an emphasis on early-stage stability under clinically relevant loading conditions. Methods Three fixation configurations were evaluated: mini-plate fixatio...
Ya-Han Chan, Yan-Yu Chen, K. Chong et al.· Bone & Joint Research· 0 citations
BACKGROUND
Internal fixation of the reoriented acetabular fragment is essential to maintain correction until osseous union. However, the underlying biomechanical principles of fixation stability remain insufficiently understood.
OBJECTIVES
To summarize the biomechanical evidence on fragment fixation following reorien...
J. Richter, André R. Zahedi, D. Ciric et al.· Orthopadie· 0 citations
TK technique showed no measurable benefit over free-lay coverage in preserving BH after maxillary MSA, and greater mesiodistal graft width was found to be correlated with higher BH values.
Emrah Bilen· European Annals of Dental Sc...· 0 citations
Background: The choice of tibial fixation device remains an important consideration in anterior cruciate ligament (ACL) reconstruction using hamstring autografts. Bioabsorbable interference screws offer potential advantages over titanium screws, although comparative clinical outcomes remain of interest. This study comp...
Ashutosh Yadav, Pushpa, Sachin Kumar· International Journal of Hea...· 0 citations
Background and Objectives: This study aimed to compare the clinical, functional, and graft-related outcomes of two tibial fixation constructs used in primary hamstring autograft anterior cruciate ligament reconstruction (ACLR): tibial cortical button fixation and bioabsorbable interference screw fixation reinforced wit...
Oktay Polat, Berk Koncalıoğlu, Mehmet B. Kuyumcu et al.· Medicina· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.