Skip to content

A Co-adaptive Few-shot Calibration Method for Improving Motor Imagery BCI Performance.

Sep 2026 · IEEE journal of biomedical and health informatics · Vol PP, pp. 1-15 · 0 citations
Medicine

TL;DR

The Co-adaptive Few-shot calibration (CFC) approach introduces MI pattern selection to provide a subject-specific assessment protocol, and incorporates meta-learning in the calibration stage to address inter-subject and inter-pattern variability and reduce calibration time.

Abstract

Motor Imagery Brain-computer Interfaces connect the human brain with external devices by imagining muscular activity, serving as one of the promising solutions for human-computer interaction. It has been successfully applied by paralyzed individuals to control assistive devices, prosthetics and exoskeletons, and several dedicated applications. However, about half of potential users exhibit MI illiteracy, which hinders its adoption in real-world settings. Calibration has been demonstrated as an effective approach to enhancing MI capabilities. Nevertheless, existing calibration methods face two critical challenges: 1) the lack of systematic protocols to guide subjects in refining their MI skills based on the outcome of the intended actions, and 2) the use of fixed, cross-subject classifiers that do not address inter-subject MI variability. This study proposes the Co-adaptive Few-shot calibration (CFC) approach. It particularly addresses the above two challenges: 1) it introduces MI pattern selection to provide a subject-specific assessment protocol, and 2) it incorporates meta-learning in the calibration stage to address inter-subject and inter-pattern variability and reduce calibration time. We carried out an experiment on 30 subjects to verify the effectiveness of CFC. The results show that after a short calibration, the subject's MI capabilities were significantly improved, with the average binary motor imagery accuracy improved from 69.50% to 77.47% (+ 7.97%) on the experiment group with 10 naive subjects. The CFC approach can help subjects find the optimal MI pattern to enhance their MI ability in a short time. This method broadens the practical usability of MI-BCI systems, making them accessible to a wider population of users.

View source

Similar papers

#artificial intelligence Preprint Aug 2026

A Hybrid Gaze-Motor Imagery BCI Framework for Effective Decision Communication

Non-invasive brain-computer interfaces (BCIs) and eye-tracking technologies offer promising communication pathways; however, motor imagery (MI)-based BCIs often suffer from low discriminability and high inter-subject variability. To mitigate these issues, this study investigates the impact of visual fixation on neural...

N. GowthamReddy, KongFatt Wong-Lin, Y. Meena · 0 citations
Open access Sep 2026

Improving the Accuracy of Motor Imagery in BCI for the Movement of Artificial Prostheses used for Disabled People

A brain-computer interface (BCI) allows users to communicate directly with an external device, such as a computer, using brain signals. These systems involve signal acquisition, temporal and spatial filtering, feature engineering, and classification before transmitting the control signal to an external device. Brain-co...

Isaac Jahanbakhshi, Shaghayegh Niavarani, Fatemeh Shahbazi et al. · 0 citations
Review Open access Sep 2026

Cross-variability decoding for motor imagery EEG signals: a comprehensive review

A comprehensive taxonomy of MI EEG cross-variability decoding studies from 2020 to 2025 is presented, systematically organizing advances in deep learning and transfer learning and critically evaluate core algorithmic approaches, including Convolutional Neural Networks, transformers, feature alignment, domain adaptation...

Li-Jun Wang, Yue-Ying Zhou, Peng-Pai Wang et al. · 0 citations
Open access Aug 2026

A confidence-gated source selection strategy for cross-session transfer in brain–computer interfaces

Cross-session variability remains a major obstacle to the reliable operation of motor imagery (MI)-based brain-computer interfaces (BCI), particularly when systems are reused across multiple days. When multiple prior sessions from the same subject are available, two key questions arise before domain transfer: which sou...

Yiming Shen, David Degras · 0 citations
2026

Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration

Recently, electroencephalography (EEG)-based brain–computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is often hindered by nonstationarity and cross-subject distribution shifts, which lead to significant intersubject inconsisten...

Kun-Kun Zhang, Ke-Hao Wu, Zhi-Tao Chen et al. · 0 citations
Open access Sep 2026

Subject-Specific Deep Learning Model for Motor Imagery Direction Decoding

A novel deep learning framework for online decoding of binary directional MI signals from the dominant hand of 20 healthy subjects using EEGNet-based convolutional filters to extract temporal and spatial features and is outperforming the existing deep learning models.

Praveen K. Parashiva, Sagila Gangadharan Kutteri, A. P. Vinod · 0 citations