2019· Journal of Science & Technology· Vol 04, pp. 48-56· 0 citations
Abstract
Due to the wide spread of power electronics equipment in modern electrical systems, the increase of the harmonics disturbance in the ac mains currents has became a major concern due to the adverse effects on all equipment. Power electronic converters are commonly used for interfacing distributed generation (DG) systems to the electrical power network. However, the unbalanced voltage compensation may cause adverse effects on the IFCs' operation such as output active power oscillation and DC link voltage variations. Moreover, since the compensation is realized through the available rating of IFCs, it is equally important to consider the effectiveness of control strategy for unbalanced voltage compensation. Specially, the first control strategy aims at minimizing the IFC's active power oscillation and reducing the adverse effects of unbalanced voltage compensation on IFC's operation. In DG systems a fast and accurate positive-sequence, fundamental grid voltage frequency and magnitude tracking is required to synchronize grid connected converter systems with the mains. The proposed System deals with a Multi level inverter for DG systems mitigating power quality issues, such as harmonics and reactive power compensation for grid-connected operation. It performs the nonlinear load current harmonic compensation, mitigates harmonics yielding more accurate and pure sine wave output. So Instead of using inverter we can use multilevel inverters in the power system equipment.
As renewable generation and power-electronic interfaces account for a growing share of power systems, reduced system inertia and weakened voltage support place greater demands on the stable operation of weak and passive networks. This paper proposes a virtual synchronous generator (VSG)-based active support strategy fo...
Wei Chen, Yun-Che Su, Fang Liu et al.· Symmetry· 0 citations
When the modular multilevel converter is connected to the grid, the voltage reference command issued by the dispatching system to the MMC is updated at 15-min intervals, but the rapid fluctuation of the DC side power can be close to a few seconds. This kind of phenomenon leads to the mismatch of time scale between th...
In the distribution side of electrical power systems, especially in industries, the non-linear and sensitive loads are increasing day by day, due to which the power quality (PQ) is degrading. The main PQ issues are voltage sags, reactive power imbalance, and harmonics, which are primarily addressed by advanced power el...
In recent years, wind power generation has attained significant attention, leading to the
installation of numerous wind power plants worldwide. Most wind turbines employ
induction generators, which typically absorb substantial reactive power (VARs) from the
grid. This reactive power demand can result in voltage drops a...
K. Archana, V. Pushparajesh· ITEGAM- Journal of Engineeri...· 0 citations
Large-scale grid integration of renewable energy and power electronic devices leads to power quality problems including grid harmonic distortion. To solve these problems, this paper proposes a V2G grid-connected harmonic mitigation strategy that combines repetitive control and PI composite control based on the bidirect...
Xiao-Rong Wan, Da-Yi Li, Yi-Zheng Zhang et al.· 2026 6th Power System and Gr...· 0 citations