Skip to content

Method Development and Validation of Promethazine HCl by Using RP-HPLC and Its Forced Degradation Studies.

Sep 2026 · Assay and drug development technologies · pp. 1540658X261486549 · 0 citations · 9 references
Medicine

TL;DR

The developed RP-HPLC method was found to be suitable for routine quality control analysis and stability assessment of promethazine HCl in pharmaceutical formulations.

Abstract

A simple, rapid, sensitive, and stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative determination of promethazine hydrochloride (HCl) in pharmaceutical formulations. Chromatographic separation was achieved using a SunFire® C18 column (4.6 × 250 mm, 5 µm) with a mobile phase consisting of acetonitrile and 0.1% orthophosphoric acid in water (80:20, v/v) at a flow rate of 1.0 mL/min. Detection was performed at 249 nm using a photodiode array detector. The developed method was validated according to the International Council for Harmonisation Q2 guidelines with respect to specificity, linearity, precision, accuracy, robustness, limit of detection, and limit of quantitation.The method exhibited good linearity over the concentration range of 2-64 µg/mL with a correlation coefficient (R2) of 0.9993. The percentage relative standard deviation for precision studies was below 2%, indicating satisfactory repeatability and reproducibility. Forced degradation studies were performed under acidic, alkaline, neutral, oxidative, and thermal stress conditions to evaluate the stability indicating capability of the method. Additional chromatographic peaks corresponding to degradation products were observed in acid, base, neutral, and oxidative stress conditions, while minimal degradation was observed under thermal stress. Furthermore, liquid chromatography-mass spectrometry (LC-MS) analysis was carried out to characterize the degradation products formed during stress studies. LC-MS results indicated that alkaline stress produced the highest degree of degradation, whereas thermal stress generated only minor residual impurities, confirming the relative stability of promethazine HCl under thermal conditions. The developed RP-HPLC method was found to be suitable for routine quality control analysis and stability assessment of promethazine HCl in pharmaceutical formulations.

View source

Similar papers

Open access Oct 2026

RP-HPLC Method & Validation For Estimation Of Flurbiprofen In Bulk And Its Formulation

A simple, precise, accurate, and validated Reverse Phase High-Performance Liquid Chromatographic (RP-HPLC) method was developed for the estimation of Flurbiprofen in bulk drug and pharmaceutical dosage forms. Chromatographic separation was achieved using a C18 column under isocratic conditions. The optimized mobile pha...

Somnath S. Davkhar, S. Jain · 0 citations
Open access Sep 2026

Analytical Method Development and Validation of Finerenone in Bulk and Formulation by HPLC

A simple, rapid, precise, accurate, and robust reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the quantitative determination of finerenone in bulk drug substance and pharmaceutical tablet formulation. Chromatographic separation was achieved on a C18 column employi...

Akanksha A. Borhade, P. Dighe · 0 citations
Open access Nov 2026

Development and Validation of a Stability- Indicating UPLC Method for Assay of Tagoprazon Pharmaceutical Formulations

A simple, rapid, accurate, and stability-indicating Ultra-Performance Liquid Chromatography (UPLC) method was developed and validated for the quantitative determination of Tegoprazan in bulk drug and pharmaceutical tablet formulations. The chromatographic separation was achieved using an Agilent Eclipse Plus C18 column...

K. Kumar, V. Sastry · 0 citations
Open access Oct 2026

Method Development and Validation of RP-HPLC Method for Determination of Cetirizine and Montelukast in Bulk and Pharmaceutical Formulation

A precise, rapid, and reproducible Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the simultaneous estimation of Cetirizine and Montelukast in both bulk drug substances and pharmaceutical formulations. The chromatographic separation was carried out using a Phenomen...

P. Samuel, C. Sunitha · 0 citations
Open access Oct 2026

Development, Optimization and Validation of A Robust RP-HPLC Method for The Quantitative Determination of Oxcarbazepine in Tablet Dosage Form

A robust reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed, optimized and validated for quantitative determination of oxcarbazepine in tablet dosage form. The analytical procedure used a 250 × 4.6 mm, 5 µm C18 column, a phosphate-buffer/acetonitrile mobile-phase system, a flow rate o...

B. E. Jose, P. Karthika, M. D. Rani et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.