Skip to content
Open access

Intra‐MRI Head Motion Tracking and Correction: A Quantitative In Vivo Evaluation Framework

Aug 2026 · NMR in Biomedicine · Vol 39 · 0 citations · 42 references
Medicine

TL;DR

While image quality metrics suggested superior overall correction with MOS, an in vivo framework provided a more detailed characterization of in vivo performance differences, Notably, the framework detected a subtle improvement in FatNav performance with neck masking, an effect uncaptured by conventional image quality metrics.

Abstract

Despite numerous magnetic resonance imaging (MRI) head motion mitigation strategies, the lack of rigorous evaluation limits their optimization and clinical adoption. We propose an in vivo framework combining a visual instruction system for reproducible head motion with reference standard interpose displacement estimation to assess intra‐MRI tracking accuracy and precision. Its utility is demonstrated by comparing a markerless optical system (MOS) and a fat‐signal navigator (FatNav). Six participants underwent 3T T1‐weighted brain MRI with a FatNav module, performing visually guided 2° and 4° head rotations around the X‐ and Z‐axes using MOS feedback. T1‐weighted images were acquired at seven distinct head poses. MOS and FatNav motion estimates were compared against rigid registration of the T1‐weighted images, which served as the reference standard. MOS‐ and FatNav‐corrected images for the three successive head rotations were also compared using the structural similarity index measure (SSIM), peak signal‐to‐noise ratio (PSNR), and a focus measure. FatNav accuracy was inferior for translations (p < 0.001) and 2°–4° rotations but improved to match MOS for subtle pitch+ and yaw+, even surpassing it for subtle yaw−. Meanwhile, MOS precision was higher for yaw+ than yaw− (p < 0.001) but inferior to FatNav for pitch+ (p = 0.041). MOS better restored T1‐weighted image fidelity, yielding higher SSIM, PSNR, and focus (p < 0.01). Notably, the framework detected a subtle improvement in FatNav performance with neck masking, an effect uncaptured by conventional image quality metrics. In conclusion, while image quality metrics suggested superior overall correction with MOS, our framework provided a more detailed characterization of in vivo performance differences.

Read PDF

Similar papers

Open access Aug 2026

Impact of MRI slice thickness and fiducial marker orientation on geometric accuracy in multi‐echo GRE imaging for prostate radiotherapy planning

Abstract Background Precise target definition in prostate radiotherapy requires accurate computed tomography (CT)‐magnetic resonance imaging (MRI) image registration using gold fiducial markers (GFMs). While multi‐echo gradient recalled echo (ME GRE) sequences facilitate GFM identification, the quantitative impact of a...

Aika Hayashi, Yasukata Takahashi, N. Sanuki et al. · 0 citations
Conference Aug 2026

Lesion-robust longitudinal brain CT registration via MR-guided image translation

Experimental results demonstrate that the proposed lesion-robust framework for longitudinal brain CT registration based on MRguided image translation consistently outperforms conventional intensity-based registration methods as well as existing image-translation–assisted strategies in both quantitative metrics and visu...

Zijun Cheng, Hui-Xiang Zhuang, Yue Guan et al. · 0 citations
Jul 2026

Comparison of accelerated MRI protocol approaches for clinical assessment of the knee.

Accelerated 2D DL, 3D Cube, and 3D qDESS protocols demonstrated diagnostic agreement and diagnostic image quality comparable to the conventional knee MRI protocol while reducing scan time to ~ 6 min.

Ananya Goyal, J. MacKay, M. Petterson et al. · 0 citations
Open access Jul 2026

Overcoming pitfalls in multi-stack diffusion MRI for tractography reconstruction of skeletal muscles

Accurate in vivo characterization of skeletal muscle structure is essential for understanding muscle function, assessing pathologies, and developing musculoskeletal models. Magnetic resonance imaging (MRI) and diffusion MRI enable visualization of muscle morphology and fibre architecture in vivo, but imaging skeletal m...

Manuela Zimmer, G. Handsfield, Paul Condron et al. · 0 citations
Open access Jul 2026

AAPM Task Group 333 Report: Quality assurance for MRI‐guided focused ultrasound body systems

A quality assurance (QA) procedure for magnetic resonance‐guided focused ultrasound (MRgFUS) body systems was developed and tested at five institutions. The QA procedure is based on a custom‐designed phantom with tissue‐mimicking acoustic, MR, and thermal properties specific for MRgFUS. The data acquisition includes as...

Keith A Wear, D. Parker, Allison Payne et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.