Skip to content
Review Open access

A Self-Controlled Benchmark of Retrieval-Augmented Generation for Large Language Models on Clinical Guideline Questions

Aug 2026 · Diagnostics · Vol 16 · 0 citations · 33 references
Medicine

Abstract

Background/Objectives: Large language models (LLMs) show promise for clinical decision support, yet their accuracy in interpreting specialized medical guidelines remains uncertain. Retrieval-augmented generation (RAG) may enhance performance by grounding responses in authoritative knowledge bases. This study aimed to compare the accuracy, comprehensiveness, and safety of RAG-enhanced versus standard LLMs for answering clinical questions derived from the German S3 guideline for oral cavity carcinoma. Methods: We conducted a prospective, single-blind benchmark study evaluating six LLMs: one RAG-enhanced model (Custom GPT with guideline access), one consensus-based model (ConsensusGPT), and four standard models (DeepSeek-V3.2, Mistral Small 3.2, Qwen3-Next-80B, GPT-OSS-120B). Fifty clinical questions covering 17 guideline domains were presented to each model three times, yielding 900 evaluations. Three expert reviewers assessed responses using 5-point Likert scales for accuracy, comprehensiveness, and clarity, under a single-blind procedure, the effectiveness of which was tested by a pre-specified manipulation check. We then ran a paired within-model experiment in which each base model was queried with and without guideline access through a transparent, openly released retrieval pipeline, and scored every response with a condition-blind automated judge alongside deterministic retrieval metrics computed from the logs. Secondary outcomes included hallucination rates and guideline citation behavior. Inter-rater reliability was assessed using intraclass correlation coefficients (ICCs). Results: In a paired within-model design that held each base model fixed, adding transparent guideline retrieval improved accuracy—significantly in the three weaker open-weight models (Mistral, Qwen3, and GPT-OSS) and directionally in the already-strong DeepSeek and GPT-5 bases. Because a pre-specified blinding check found that experts could still identify retrieval-augmented answers with 98.5% accuracy, we anchored causal interpretation on measures that do not depend on the human raters, ranked by their independence: deterministic, log-derived retrieval metrics first, and then an automated, condition-blind LLM judge, whose agreement with the experts (Spearman ρ = 0.81, 95.7% within-one agreement) establishes shared calibration rather than independence from their bias. Deterministically from the retrieval logs, citation groundedness rose from 0% to 51–89% and retrieval recall@5 was 92%. On the judge, content-level hallucination fell from 42% to 4% and accuracy rose by a pooled +0.64 points (95% CI 0.47–0.80); the accuracy gain persisted after adjustment for response length (+0.48, 95% CI 0.22–0.73), which retrieval shortened rather than lengthened. The accuracy gain was large for weaker base models and small or non-significant for already-strong ones, whereas the hallucination and auditability gains were consistent across all models. The human ratings reproduced the judge’s accuracy effect (+0.61, 95% CI 0.49–0.74), and GPT-5 run through the transparent pipeline showed no significant difference from the proprietary Custom GPT (judge accuracy 4.48 vs. 4.58). Conclusions: Guideline retrieval yields a reproducible, largely base-independent improvement in the safety and auditability of LLM answers to clinical guideline questions, with accuracy gains concentrated in weaker base models. Because retrieval-augmented answers are recognizable to experts, rigorous evaluation should rely on rater-independent measures, and residual hallucination continues to require human oversight.

Read PDF

Similar papers

Open access Aug 2026

Retrieval-augmented generation for medical question answering: a multi-metric performance evaluation

The proposed framework offers a practical and scalable approach to mitigating hallucinations without requiring task-specific fine-tuning, highlighting the potential of retrieval-augmented approaches for trustworthy artificial intelligence (AI)-assisted healthcare applications.

Yunus Kökver · 0 citations
Review Open access Aug 2026

Benchmarking large language models for question answering on German clinical practice guidelines

The observed performance gains with RAG support the use of LLMs augmented with quality-assured external knowledge in the German healthcare context, while strong performance of open-weight models suggests potential for on-premises deployment in privacy-sensitive clinical environments.

Johannes Schwietering, G. Lichtner · 0 citations
Preprint Jul 2026

Faithful by Design: Evaluating and Improving LLM-Generated Clinical Trial Summaries for Multi-Stakeholder Audiences

A benchmark evaluation framework for measuring the faithfulness of LLM-generated clinical trial summaries across three stakeholder audiences is introduced and a knowledge-graph-augmented retrieval system was developed and evaluated, producing statistically significant improvements in NLI-based faithfulness scores.

Robert W. Williams · 0 citations
Preprint Jul 2026

A rubric-based controlled comparison of frontier language models on expert-authored clinical reasoning tasks

Multiple-choice medical benchmarks are increasingly saturated, and recent rubric-based evaluations such as HealthBench have shown that open-ended clinical performance is far from solved - its"Hard"subset top score remains 32%. We present a small, deliberately difficult evaluation dataset of five clinician-authored clinical scenarios spanning four specialties (anaesthesia, internal/family medicine, emergency medicine, and obstetrics), each accompanied by an atomic, weighted, MECE rubric (25-62 criteria per task; 184 criteria total) authored from a clinician-drafted golden answer. We evaluate three frontier models: GPT 5.4, Claude Opus 4.7, and Gemini 3.1 Pro. Mean rubric pass rates were 0.47 (Claude), 0.39 (GPT), and 0.37 (Gemini). The central finding is an inversion of clinical priority: the highest-weighted (weight-5, critical) criteria passed at only 32.4-41.7%, while low-stakes weight-1 criteria passed at 80-90%. 56 of 108 critical (weight-5) criteria (52%) were satisfied by no model. Three LLM autoraters reproduced expert met/not-met labels on 92.8-94.7% of 552 graded criteria. We position this as a methods-and-preliminary-findings contribution: the five tasks demonstrate a scalable, defensible pipeline ready to develop into a large-scale benchmark.

Samiha A. Ismail, Fan X. Chen, Ali Merali · 0 citations
Jul 2026

Guideline-anchored retrieval-augmented generation outperforms baseline and literature-only configurations in gynecologic oncology decision support: A pre-integration benchmark.

NCCN-anchored RAG outperformed both baseline GPT-5 and a literature-anchored clinical AI without direct guideline access, and external validation of guideline anchoring's operational importance provides external validation of guideline anchoring's operational importance.

D. Dukes, C. Yost, Runzhi Wang et al. · 0 citations