Skip to content

Testing the reliability of novel Voxel Placement approaches for Magnetic Resonance Spectroscopy

Aug 2026 · bioRxiv · 0 citations · 8 references
Biology

TL;DR

Both MGRP and SSVR improved voxel placement and metabolite measurement reproducibility compared with conventional anatomy-based placement and improved within-subject reproducibility across repeated sessions, providing a robust approach for longitudinal single-voxel MRS studies.

View source

Similar papers

Open access Aug 2026

Comparative Evaluation of Single-Voxel and Multi-Voxel Proton Magnetic Resonance Spectroscopy Using Small-Sized Voxels in Healthy Beagle Dogs: A Pilot Study

While small-voxel SVS is technically feasible and reduces scan time, these findings represent protocol-specific descriptive data in a small sample of healthy dogs and do not establish clinical reference values or diagnostic accuracy.

Jong-Bong Lee, Gunha Hwang, Seokmin Lee et al. · 0 citations
Open access Aug 2026

Reproducibility of Volumetric Analysis using Ultra-Low-Field Portable Magnetic Resonance Imaging

Qualitative similarities between volume measurements in adults and the questions of reproducibility through test-retest reliability and external validity using recent software updates to the Hyperfine Swoop system constitute a crucial foundation for the clinical utility of 64 mT MRI in monitoring brain volume loss over...

M. Stockbridge, Rex Wang, V. Neal et al. · 0 citations
Open access Aug 2026

A multi-b-value test-retest diffusion MRI brain dataset for model validation and reproducibility assessment

A new densely sampled longitudinal test-retest diffusion-weighted MR dataset of the brain is introduced and potential applications include assessing longitudinal reproducibility and reliability of quantitative metrics, evaluating robust and outlier-resistant estimation techniques, investigating experimental factors aff...

Tomasz Pieciak, Irene Guadilla, Dominika Ciupek et al. · 0 citations
Open access Sep 2026

Human fMRI at 11.7T: Assessing feasibility, stability, and reliability on the Iseult scanner

The results demonstrate the feasibility and reliability of whole-brain human fMRI at 11.7T and constitute a first-quality control milestone to further increase resolution at that field strength and demonstrate the feasibility and reliability of the Default Mode Network in resting state.

Joseph Obriot, Z. Amor, Matthias Serger et al. · 0 citations
Open access Jul 2026

Comparative Analysis of Four Commercially Available Artificial Intelligence Software for Brain Volumetry

Background/Objectives: Automated brain volumetry is increasingly integrated into the work-up of several neurological disorders, yet between-software variability may limit the interchangeability of absolute measures. This study aimed to assess inter-software variability, agreement, and interchangeability among four clin...

Gaspare Saltarelli, Giovanni Di Cerbo, Antonio Innocenzi et al. · 0 citations