Skip to content
Open access

Functional versus mechanical alignment in robotic primary total knee arthroplasty: A meta-analysis

Sep 2026 · SICOT-J · Vol 12, pp. 50 · 1 citation · 45 references
Medicine

TL;DR

Robotic FA was associated with fewer soft-tissue releases and greater early improvement in reported knee motion, but these early advantages did not translate into superior functional improvement by 1 year.

Abstract

Introduction: Functional alignment (FA) has emerged as a robot-enabled, patient-specific strategy in total knee arthroplasty (TKA), aiming to individualize component positioning and knee balance within predefined safety limits. However, whether robotic FA provides clinically meaningful advantages over robotic mechanical alignment (MA) remains uncertain. This meta-analysis compared robotic FA versus robotic MA in primary TKA. Methods: Medline, the Cochrane Library, and Google Scholar were searched from inception to December 29, 2025, for comparative studies evaluating FA versus MA in robotic primary TKA. Outcomes included additional soft-tissue release, reported knee motion, Forgotten Joint Score-12 (FJS-12), 1-year functional score improvement using Oxford Knee Score or converted Western Ontario and McMaster Universities Osteoarthritis Index scores, and operative duration. Continuous outcomes were pooled as mean differences (MDs), and dichotomous outcomes as odds ratios (ORs). Results: Six studies including 645 TKAs were included. MA was associated with higher odds of requiring additional soft-tissue release compared with FA (OR = 5.38; 95% CI: 2.71 to 10.69; P < 0.00001). FA showed greater early improvement in reported knee motion at ≤6 weeks (MD = −4.64°; 95% CI: −7.07 to −2.21; P = 0.0002), but this difference was no longer significant at 6 months (MD = −1.13°; 95% CI: −8.24 to 5.98; P = 0.76). FJS-12 scores were similar at 3 months but favored FA at 6 months (MD = −10.74; 95% CI: −13.65 to −7.83; P < 0.00001), although this did not reach the established threshold for clinical importance. Functional score improvement at 1 year was similar between groups. Operative time statistically favored FA, although the difference was small. Conclusion: Robotic FA was associated with fewer soft-tissue releases and greater early improvement in reported knee motion, but these early advantages did not translate into superior functional improvement by 1 year. Longer-term standardized comparative studies are required.

Read PDF

Similar papers

Open access Oct 2026

Functional versus mechanical alignment in robot-assisted total knee arthroplasty: a prospective randomized single-center trial

Background. Despite substantial advances in total knee arthroplasty (TKA), a considerable proportion of patients remain dissatisfied with surgical outcomes. One possible explanation is the discrepancy between restored joint biomechanics and the patient’s native anatomy. Functional alignment has recently emerged as a pr...

G. Airapetov, A. Prizov, A. Daniliyants et al. · 0 citations
Open access Sep 2026

Functional alignment with robotic-assisted total knee arthroplasty is associated with reduced early postoperative pain and alignment outliers compared to mechanical alignment with conventional total knee arthroplasty: a prospective cohort study

Introduction: Robotic-assisted total knee arthroplasty (RATKA) has been introduced to enhance surgical precision, alignment, and soft-tissue balancing, thus enabling the advent of numerous alignment philosophies including functional alignment (FA). This study aimed to compare early clinical outcomes, patient-reported o...

Wai-Kit Wong, N. Che-Kamaruddin, Patrick Ze-En Ng et al. · 0 citations
Open access Oct 2026

Conventional versus robotic total knee arthroplasty – a comparative study of accuracy, alignment and early functional results

Background: Restoration of mechanical alignment and optimization of functional outcomes are critical for total knee arthroplasty (TKA). Robotic systems aim to improve the accuracy of bone cuts and reduce malalignment. Evidence from Indian populations remains limited. Methods: The present study was a prospective, non-ra...

Sathiya Reddy, N. Vutharkar, S. S. T. Rongala et al. · 0 citations
Open access Sep 2026

Comparative Analysis of Robotic-Assisted and Manual Total Knee Arthroplasty in Patients with Extra-Articular Deformities: A Propensity Score-Matched Prospective Cohort Study

RA-TKA was associated with a significantly lower rate of mechanical axis outliers and higher functional outcome scores at 12 months compared with manual TKA in patients with EAD, and the advantage may be most pronounced in severe and multiplanar deformities, but adequately powered studies are needed to confirm these fi...

G. Ayrapetov, D. Suleymanyants, I. Dmitrov et al. · 0 citations
Review Nov 2026

Comparative Effectiveness of Contemporary Alignment Strategies in Total Knee Arthroplasty: A Systematic Review and Network Meta-Analysis.

BACKGROUND Patient-specific alignment strategies are increasingly used in total knee arthroplasty (TKA), but comparative clinical benefit over mechanical alignment (MA) remains uncertain. We compared contemporary alignment strategies using the Forgotten Joint Score (FJS) as the primary outcome. METHODS There were fou...

Guan-Ren Tan, Hui-Shan Angela Lim, Leah Robin Thorpe et al. · 0 citations
Review Oct 2026

Postoperative neutral coronal alignment does not confer superior functional outcomes after robotic-assisted total knee arthroplasty: A retrospective review

Neutral coronal alignment has historically been considered a primary target in total knee arthroplasty (TKA). However, whether restoration of a neutral mechanical axis translates into superior clinical outcomes remains controversial. This study aimed to determine whether achieving a neutral postoperative arithmetic...

C. Burgio, F. Bosco, C. Cobisi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.