Skip to content
Open access

Predictive Value of the Electrical Risk Score for Ventricular Arrhythmias in Heart Failure Patients with Primary Prevention Implantable Cardioverter Defibrillators

Sep 2026 · Journal of Clinical Medicine · Vol 15 · 0 citations · 31 references
Medicine

TL;DR

The electrical risk score (ERS) was associated with ventricular arrhythmia-related ICD shocks in HF patients undergoing primary prevention ICD implantation and may identify patients at increased arrhythmic risk and guides follow-up and ICD management.

Abstract

Background: Implantable cardioverter defibrillators (ICDs) are essential for the primary prevention of sudden cardiac death in heart failure (HF); however, appropriate shocks increase mortality and impair quality of life. The electrical risk score (ERS) is an electrocardiographic (ECG)-based composite index with proven prognostic value, but its ability to predict ventricular arrhythmias in HF remains unclear. This study aims to evaluate the predictive value of the ERS for ventricular arrhythmia-related ICD shocks in HF patients undergoing primary prevention ICD implantation. Methods: In this study, 91 patients with HF were followed for 12 months after ICD implantation. The ERS was calculated from baseline ECGs. Patients were grouped based on ERS (<3 vs. ≥3), according to receiver operating characteristic curve analysis. Multivariate logistic regression was used to evaluate predictors of appropriate ICD shocks, and predictive performance was compared using the DeLong test. Results: Thirty-five patients (38.5%) experienced at least one appropriate ICD shock. The median ERS was significantly higher in the shock group compared to the non-shock group (p < 0.001). Patients with ERS ≥ 3 had significantly higher rates of the anti-tachycardia pacing therapy (p < 0.001) and HF-related hospitalization (p = 0.004). ERS was an independent predictor of ICD shocks (p < 0.001), with superior discriminative performance (AUC 0.882) compared to most ECG markers, including frontal QRS T angle, QRS duration, Tp-e interval, and heart rate. Conclusions: The ERS was associated with ventricular arrhythmia-related ICD shocks in HF patients undergoing primary prevention ICD implantation. The ERS may identify patients at increased arrhythmic risk and guides follow-up and ICD management.

Read PDF

Similar papers

Open access Oct 2026

Evaluation of primary prevention ICD efficacy in late elderly heart failure patients: a multicenter study

The benefit of primary prevention implantable cardioverter defibrillator (ICD) in heart failure (HF) patients aged ≥75 years, particularly those with significant non-cardiac comorbidities, is questionable. We aimed to evaluate the clinical yield of primary prevention ICD in late-elderly HF patients. A mult...

A. Brin, O. Koren, A. Demitriev et al. · 0 citations
Nov 2026

Ventricular arrhythmia-heart failure interaction and mortality in ICD recipients after myocardial infarction.

In ICD recipients with persistent LV dysfunction following MI, VA and HF events are bidirectionally associated and independently associated with mortality and the VA-HF association was strongest for shock-treated arrhythmias.

Matthieu Echivard, J. Sellal, J. McMurray et al. · 0 citations
Open access Sep 2026

The impact of inappropriate shocks in implantable cardioverter-defibrillators in contemporary clinical practice

Implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds) are effective in preventing sudden cardiac death. However, inappropriate shocks (Inap-S) may impair quality of life and have been associated with adverse clinical outcomes. This study evaluated the incidence...

J. Pereira, S. Andraz, L. Hamann et al. · 0 citations
Open access Oct 2026

Risks of appropriate implantable cardioverter defibrillator therapy and cardiac hospitalization are increased around device-detected atrial high-rate episodes longer than 6 minutes

The use of cardiac implantable electronic devices (CIEDs) with an atrial lead allows continuous detection of atrial high-rate episodes (AHRE), providing valuable insights into the incidence and clinical relevance of subclinical atrial fibrillation in patients with CIEDs. The prognostic significance of device-dete...

N. Nørgaard, C. Witt, M. Kronborg et al. · 0 citations
Open access Sep 2026

Myocardial Work Index Dispersion as a Potential Predictor of Ventricular Arrhythmias in Patients with Heart Failure with Reduced Ejection Fraction

In this cohort, MWI dispersion showed the highest single-parameter discrimination for VAs among the echocardiographic variables tested, and its combination with RA area gave the best model.

M. Dąbrowska, M. Potapowicz-Krysztofiak, Patrycja Życzkowska et al. · 0 citations
Open access Oct 2026

Cardiac magnetic resonance-based prediction of ventricular arrhythmic events in non-ischemic cardiomyopathy: derivation and external validation in the international multicenter IMPROVE-NICM Study

Risk stratification for sudden cardiac death (SCD) in non-ischemic cardiomyopathy (NICM) remains suboptimal. Current guidelines recommend primary prevention implantable cardioverter-defibrillator (ICD) implantation in patients with LVEF <35% (NYHA II–III) (1); however, its limited predictive accuracy (2,3) unders...

A. Latini, G. Falasconi, C. Panico et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.