Non-contrast renal MR angiography: a within-subject comparison of imaging performance at 1.5 T, 3 T, and 5 T

Aug 2026 · BMC Medical Imaging · 0 citations

TL;DR

These findings provide quantitative baseline data for normal renal vasculature and support further clinical validation of NC-MRA protocols in patients with renal artery disease or contraindications to gadolinium-based contrast agents.

Abstract

This within-subject study compared non-contrast renal MRA (NC-MRA) at 1.5 T, 3 T and 5 T via comprehensive quantitative and subjective imaging assessments, and further explored imaging disparities between standard and high-resolution 5 T sequences. Thirty-nine healthy volunteers underwent standardized same-day non-contrast MRA scans across the three magnetic field strengths; both standard and high-resolution protocols were implemented on the 5 T scanner. Quantitative parameters including apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR) and vessel sharpness were calculated using the erector spinae muscle as the local noise reference, an approach intended to reduce g-factor related noise bias between different scanners. Two senior radiologists performed subjective image scoring independently as blinded readers. All images were fully anonymized by removing scanner and sequence identifiers, and the presentation order of image datasets was randomly rearranged for each reviewer to minimize potential reading bias. Statistically significant inter-group differences were detected for all quantitative indicators (all p  < 0.05). The 5 T standard protocol yielded the highest median aSNR and aCNR values, while the 5 T high-resolution sequence achieved optimal vessel sharpness and clearer visualization of distal subsegmental renal branches. Both 5 T protocols were superior to 1.5 T and 3 T sequences in terms of artifact suppression, vascular contour delineation and subjective diagnostic confidence. The two tested 5 T NC-MRA protocols were associated with improved image-quality metrics and artifact scores in healthy volunteers. These findings provide quantitative baseline data for normal renal vasculature and support further clinical validation of NC-MRA protocols in patients with renal artery disease or contraindications to gadolinium-based contrast agents.

Read PDF

Similar papers

Open access Aug 2026

Evaluation of the usefulness of post-contrast T2-FLAIR sequence MRI in the diagnosis of intracranial pathology

Post-contrast T2 FLAIR, as a more sensitive imaging sequence, was supported by its superior ability to detect modest enhancement and define lesion borders, as well as its superior ability to detect modest enhancement and define lesion borders.

Hemlata Sarkar, Sibani Patro, Neekita Meher et al. · 0 citations
Open access Aug 2026

Simultaneous 3D structural-functional assessment of pediatric lung using 0.55-T MRI: a feasibility study

Simultaneous structural-functional lung imaging in a single free-breathing acquisition was feasible in this cohort of older awake pediatric participants using 0.55-T MRI, with structural images suitable for evaluating major pulmonary findings and quantitative ventilation metrics correlating strongly with PREFUL.

Xin Miao, N. Lee, HaiThuy N. Nguyen et al. · 0 citations
Jul 2026

Comparison of accelerated MRI protocol approaches for clinical assessment of the knee.

Accelerated 2D DL, 3D Cube, and 3D qDESS protocols demonstrated diagnostic agreement and diagnostic image quality comparable to the conventional knee MRI protocol while reducing scan time to ~ 6 min.

Ananya Goyal, J. MacKay, M. Petterson et al. · 0 citations
Open access Jul 2026

Comparative Evaluation of Magnetic Field Strength and Fat Suppression for Magnetic Resonance Sialography in Healthy Dogs.

Findings indicate that MR sialography may be valuable for assessing the mandibular-sublingual salivary duct complex, a common site of salivary diseases in dogs, and may provide a normal reference for future studies on salivary gland diseases in dogs.

Seul-Bit Shin, Nohwon Park, Yu-Jin Jung et al. · 0 citations
Jul 2026

Intra-vendor inter-scanner agreement of negative-HU measurements on fast kV-switching dual-energy CT virtual monoenergetic imaging: a phantom study

VMI shows predictable energy-dependent behavior for negative-HU materials, but inter-scanner bias increases for strongly negative values and low-dose conditions, and water-reference behavior can influence stability; scanner-aware interpretation and phantom-based harmonization are warranted for quantitative evaluation i...

Norimi Nishiyama, T. Masuda, Junnichi Nakagawa et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.