Skip to content

Effect of build orientation on marginal and internal discrepancies of zirconia crowns fabricated by using digital light processing 3D printing: A clinical study.

Jul 2026 · The Journal of prosthetic dentistry (Print) · 0 citations · 31 references
Medicine

TL;DR

Zirconia crowns fabricated at 0-degrees build orientation using the TD-6 DLP printer and 3DCera 3Y TZP slurry exhibited marginal and internal discrepancies comparable with those of Ceramill Zolid FX 4Y PSZ conventionally milled crowns, whereas 45- and 90-degree build orientation resulted in inferior adaptation, particularly at the occlusal surface.

Abstract

STATEMENT OF PROBLEM Digital light processing (DLP) 3-dimensional (3D) printing enables the additive fabrication of monolithic zirconia crowns; however, the effect of build orientation on their marginal and internal discrepancies in vivo, relative to conventionally milled zirconia crowns, remains insufficiently characterized.

Purpose

The purpose of this clinical study was to compare the marginal and internal discrepancies of zirconia crowns fabricated by conventional milling and by DLP 3D printing and to evaluate the influence of build orientation (0, 45, and 90 degrees) on the fit of DLP- printed crowns. MATERIAL AND

Methods

Ten participants requiring a single posterior zirconia crown in the maxilla or mandible were enrolled. For each participant, 4 crowns with identical designs were fabricated: 1 milled crown (Ceramill Motion 2; Amann Girrbach AG) and 3 DLP-printed crowns (TD 6; 3D Controls Co Ltd) at build orientations of 0, 45, and 90 degrees. 4Y PSZ zirconia blocks (Ceramill Zolid FX; Amann Girrbach AG) and a 3Y TZP zirconia slurry (3DCera; 3D Controls Co Ltd) were used. The silicone replica technique (Fit Checker; GC Corp) was used to measure the absolute marginal discrepancy (AMD), marginal gap (MG), and internal discrepancies at the chamfer, axial, line angle, and occlusal regions. Replica thicknesses were quantified under a digital microscope. Data were analyzed with a 1-way repeated measures analysis of variance, with fabrication condition treated as a within-subject factor. Post hoc pairwise comparisons were adjusted with the Holm procedure, and partial η2 values were calculated to quantify effect size (α=.05).

Results

Fabrication condition significantly affected AMD, MG, chamfer discrepancy, angle discrepancy, and occlusal discrepancy in the omnibus repeated-measures ANOVA (all P<.05), but not axial wall discrepancy (P=.073). Holm adjusted pairwise comparisons showed significant differences for AMD, angle discrepancy, and occlusal discrepancy (all P<.05), whereas no adjusted pairwise difference remained significant for MG or chamfer discrepancy (P>.05).

Conclusions

Zirconia crowns fabricated at 0-degrees build orientation using the TD-6 DLP printer and 3DCera 3Y TZP slurry exhibited marginal and internal discrepancies comparable with those of Ceramill Zolid FX 4Y PSZ conventionally milled crowns, whereas 45- and 90-degree build orientations resulted in inferior adaptation, particularly at the occlusal surface. Build orientation is therefore a critical parameter for DLP printed zirconia crowns using this specific system and should be carefully controlled to achieve acceptable adaptation in clinical practice.

View source

Similar papers

Open access Aug 2026

Three-Dimensional Evaluation of Marginal Gap in Prefabricated Zirconia and 3D-Printed Pediatric Crowns

3D-printed resin crowns exhibited superior marginal adaptation compared to prefabricated zirconia crowns, and among the evaluated materials, the SLA-fabricated Formlabs crowns exhibited the lowest marginal gap values.

Büşra Karaağaç Eskibağlar, İ. İpek, Ayşe Rençber Kızılkaya · 0 citations
Open access Aug 2026

Marginal and Internal Adaptation of Crowns Fabricated on Models From Digital and Conventional Impressions: An In Vitro Study.

Based on the findings of this in vitro study, digital workflows incorporating 3D-printed resin models may be considered reliable alternatives to conventional plaster models in CAD/CAM systems.

Mohanad Shomal, Şafak Külünk, Seniha Kısakürek · 0 citations
Open access Aug 2026

From milling to printing: evaluating the applicability of zirconia in restorative dentistry

PURPOSE This study compared the mechanical and optical properties of 3D-printed and milled zirconia, and evaluate the marginal and internal adaptation of crowns fabricated with 3Y-TZP and veneers fabricated with 5Y-TZP. MATERIALS AND METHODS Ninety-two disc specimens and thirty-six monolithic restorations (crowns and l...

Soo-Yeon Yoo, Seong-Kyun Kim, J. Koak et al. · 0 citations
Aug 2026

Adjustment Efficiency and Internal Fit of Screw-Retained Zirconia Crowns on Additively Manufactured Dental Casts: An In Vitro Study on the Effect of Printing Layer Thickness and Digital Implant Analog Design.

PURPOSE To evaluate how the layer thickness of additively manufactured casts and implant analog design influence the adjustment efficiency and internal fit of screw-retained zirconia crowns, compared with those adjusted on conventional stone casts. MATERIALS AND METHODS A master mandibular model with an implant and i...

Mohamed El Gedaily, Mustafa Borga Donmez, Munir Demirel et al. · 0 citations
Jul 2026

Effect of the build angle on the accuracy of 3D-printed definitive composite resin crowns, onlays, and laminate veneers: An in vitro study.

The build angle significantly influenced the accuracy of 3D-printed definitive composite resin restorations and may improve the manufacturing accuracy and clinical fit of 3D-printed definitive composite resin restorations.

S. Atasoy, S. Karademir, Onurcan Akgün et al. · 0 citations