Skip to content
Open access

A Novel Smart Facility Sustainability Optimization Algorithm for Energy-Efficient Facilities Management Using IoT and Predictive Analytics: A Comparative Performance Evaluation Against Genetic Algorithms and Particle Swarm Optimization

2025 · International Journal of Engineering and Computational Applications · 0 citations

Abstract

Facility energy management remains a critical challenge for modern smart buildings because energy-intensive assets such as heating, ventilation, and air-conditioning systems, lighting networks, plug loads, ventilation systems, and operational equipment must be controlled without compromising occupant comfort, operating cost, carbon performance, or equipment reliability. This paper proposes a novel Smart Facility Sustainability Optimization Algorithm (SFSO) for energy-efficient facilities management using Internet of Things sensor data and predictive analytics. The proposed framework integrates smart meters, occupancy sensors, indoor environmental sensors, equipment-status data, weather variables, electricity tariff signals, renewable-energy availability, and carbon-intensity indicators into a predictive optimization architecture. A Long Short-Term Memory forecasting model was used to estimate short-term facility energy demand and achieved a mean absolute error of 8.91 kWh, root mean square error of 12.76 kWh, mean absolute percentage error of 4.37%, and coefficient of determination of 0.966. The proposed SFSO algorithm was comparatively evaluated against Genetic Algorithm and Particle Swarm Optimization using energy saving, operating-cost reduction, carbon-emission reduction, comfort violation rate, peak-load reduction, maintenance-risk reduction, convergence speed, computational time, and normalized fitness value as performance indicators. Simulation-based benchmark results showed that SFSO achieved 26.78% energy saving, 32.37% operating-cost reduction, 31.87% carbon-emission reduction, 28.76% peak-load reduction, and 31.60% maintenance-risk reduction. It also recorded the lowest comfort violation rate of 2.10%, the best normalized fitness value of 0.501, and convergence within 48 iterations. The results indicate that SFSO provides a more adaptive, sustainability-aware, and computationally efficient optimization approach than conventional GA and PSO for smart facility energy management.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.