Skip to content

Evaluation of external quality assessment results of 15 clinical laboratory quality indicators in China from 2019 to 2021.

Oct 2026 · Clinica chimica acta; international journal of clinical chemistry · pp. 122865 · 0 citations · 7 references
Medicine

TL;DR

Overall laboratory quality improved from 2019 to 2021, and defects in tests covered by IQC and inter-laboratory comparison require targeted improvements and sustained monitoring of quality indicators.

Abstract

Objectives

This study analyzed external quality assessment (EQA) results for 15 clinical laboratory quality indicators (QIs) in China from 2019 to 2021 to evaluate error-influencing factors, benchmark performance against international standards and inform preliminary quality specifications.

Methods

Data for 15 QIs were collected via a web-based EQA system from 2019 to 2021. Variations across years were analyzed using descriptive statistics and Kruskal Wallis H test.

Results

Participation rates exceeded 75% for most indicators. Specimen acceptability indicators improved significantly over time. Pre-examination and intra-laboratory turnaround times (TATs) for routine and stat samples remained generally stable over the study period, except for a slight but significant increase in intra-laboratory TAT for stat samples (p < 0.001). The median rate of tests covered by an EQA-proficiency testing (PT) control reached 100%, whereas the rates of tests covered by internal quality control (IQC) and inter-laboratory comparison required improvement. The median rate of unacceptable performances in EQA-PT schemes from 2019 to 2021 was 0%, while the 75th percentile reached nearly 4%. This finding reveals considerable performance variation among individual laboratories. Reporting-related indicators yielded satisfactory results. Most laboratories achieved 100% for timely critical value notification, despite statistically significant inter-annual variations (p < 0.05).

Conclusions

Overall laboratory quality improved from 2019 to 2021. Deficiencies in tests covered by IQC and inter-laboratory comparison require targeted improvements and sustained monitoring of quality indicators.

View source

Similar papers

Quality Indicator-Driven Six Sigma Scale Assessment of Extra-Analytical Phases in Clinical Chemistry Laboratory-Insights from a Tertiary Care Hospital.

BACKGROUND In recent years, the error rate in the analytical stage of laboratory testing has been drastically reduced due to automation, good-quality reagents, standardized assays, and increased participation of laboratories in proficiency testing programs. Nevertheless, high error rates in extra-analytical phase remai...

J. Sharma, Roopali Rajput, Himanshu Sharma et al. · 0 citations
Oct 2026

A-272 Benchmarking as a Tool for Performance Evaluation in Clinical Laboratory Quality Indicators

Although some results did not fully achieve the established internal targets, benchmarking analysis demonstrated performance comparable to that observed in peer laboratories, highlighting the importance of external evaluation for a more comprehensive interpretation of quality indicators.

S. Tufik, J. Banzato, Jennifer Alves et al. · 0 citations
Open access Oct 2026

Comparative analysis of quality indicators in two ISO 9001:2015-certified community pharmacies (2020-2025)

Objective To comparatively analyse the results of selected quality indicators from the quality management system certified in accordance with ISO 9001:2015 in two community pharmacies during the period 2020-2025. Methods A retrospective comparative study was conducted in two community pharmacies certified according to...

Damià Barris Blundell, Gema Benítez-Pacheco, Miguel Ángel Mercado-Cano et al. · 0 citations
Oct 2026

A-307 Determining risk-based internal quality control frequency for biochemical testing using Sigma metrics and the QC Constellation tool

Risk-based internal quality control (IQC) has been increasingly adopted in clinical laboratories to enhance analytical quality and patient safety. ISO 15189:2022 recommends designing IQC plans based on risk assessment rather than applying fixed QC frequencies. Sigma metrics combined with the QC Constellation tool...

S. Nguyễn · 0 citations
Review Sep 2026

Development and Content Validation of a Clinical Coding Quality Audit Instrument: A Modified Delphi Study

The IAMPK provides a standardised, multidimensional, and content-validated framework for evaluating clinical coding quality, and offers a strong foundation for future psychometric evaluation and implementation to support consistent clinical coding quality assessment and continuous quality improvement in health informat...

Sri Sugiarsi · 0 citations
Oct 2026

The Current Status of CA15-3 Measurement Based on a Commutable External Quality Assessment Program.

BACKGROUND The goal was to evaluate the external quality assessment (EQA) performance of breast cancer-related tumor marker CA15-3. METHODS CA15-3 EQA materials were distributed to each participating laboratory by cold chain transportation each round, and the laboratories returned results through the official website...

Ting-Ting Jia, Zi-Ran Zhang, Yu-Hong Yue et al. · 0 citations