Abstract
AI data-centre sustainability is usually evaluated after electricity, water and materials have already been committed. This Perspective develops ZERO as an operational governance framework that moves the decision boundary upstream through hard admissibility constraints, workload and resource-state separation, federated comparison, local vetoes and execution-time revalidation. To examine two testable properties with observed data, the revised paper adds a retrospective secondary-data evaluation across six U.S. Google data-centre locations. Public FY2024 site water reports and 2024 Google Cloud regional grid-carbon intensities were harmonised with 52 weekly county-level U.S. Drought Monitor observations, yielding 312 location-week records. A carbon-only spatial comparator selected the lowest-intensity region; ZERO then applied predeclared drought-coverage hold conditions before selecting the lowest-carbon remaining site. At county-area thresholds of 50%, 75% and 90% in moderate-to-exceptional drought (D1-D4), the carbon-only choice was held in 13, 6 and 3 of 52 weeks, respectively (25.0%, 11.5% and 5.8%). Observed state changes also reopened admissibility during the year. In the retrospective replay, observed drought conditions altered the admissible set before carbon ranking and triggered revalidation under the declared rules. The results do not establish universal drought thresholds, measured workload savings or operational superiority; those claims require operator telemetry and controlled deployment trials. ZERO moves AI data-centre resource governance upstream, before workload execution. Hard local constraints are applied before optimisation and cannot be offset by favourable soft scores. A 2024 public-data replay combines six U.S. locations with 52 weekly drought observations (312 location-week records). Drought-based HOLD rules changed the carbon-only choice in 5.8-25.0% of weeks across the declared sensitivity thresholds. Observed weekly state changes reopened admissibility and exercised ZERO revalidation over the 2024 horizon. ZERO moves AI data-centre resource governance upstream, before workload execution. Hard local constraints are applied before optimisation and cannot be offset by favourable soft scores. A 2024 public-data replay combines six U.S. locations with 52 weekly drought observations (312 location-week records). Drought-based HOLD rules changed the carbon-only choice in 5.8-25.0% of weeks across the declared sensitivity thresholds. Observed weekly state changes reopened admissibility and exercised ZERO revalidation over the 2024 horizon.
Standard data center sustainability metrics, including Power Usage Effectiveness (PUE), Water Usage Effectiveness (WUE), and Carbon Usage Effectiveness (CUE), measure a facility's resource use and emissions intensity, normalized to IT energy use, without directly representing local resource scarcity, infrastructure cap...
The rapid growth of artificial intelligence (AI) depends on interconnected water, energy, and data systems spanning infrastructure life cycles and diverse geographies, with the potential to intensify water and energy insecurity, exacerbate social inequities and lead to cascading sustainability issues globally. Yet asse...
Jin-Cheng Huang, Guo-An Xiao, Xin Lan et al.· 0 citations
As built-environment carbon research expands from quantification toward mitigation decision support, a central unresolved question is whether reported carbon advantages remain valid under the conditions governing real decisions and implementation. This review integrates bibliometric mapping and structured full-text syn...
Trang Thi Trinh, L. V. Ho, H. Pham et al.· Sustainability· 0 citations
AI is increasingly used to support decarbonization decisions across the built environment, yet the development, training, and use of AI consume energy and induce CO2e emissions. However, existing assessments often report physical-system savings while omitting AI-side emissions. Moreover, they rarely account for the mis...
Chen Xu, B. Akinci, Christopher McComb· 0 citations
Green governance provides the framework to balance these competing forces by setting standards for energy efficiency, mandating renewable energy procurement, and encouraging life-cycle sustainability assessments and ensures that the growth of digital infrastructure does not come at the expense of climate commitments, b...
Selvakumar P, S. M, Satheesh Kumar G et al.· Journal of Carbon Sequestrat...· 0 citations
Most North American drinking water mains were installed in the 1940s–1960s and are now past their design service life, especially cast-iron mains. Most existing lifecycle costing frameworks work with specific levels of data that smaller utilities rarely hold. Many also omit discounting, which obscures the net present v...
Saad Ibrahim, B. Kalyan, Haider Ibrahim et al.· Water· 0 citations