Jul 2026· Journal of Vascular Surgery· 0 citations· 12 references
Medicine
TL;DR
MA was routinely performed in elective pEVAR and best practices in radiation safety were rarely achieved with a high rate of direct operator exposure to the beam of radiation, suggesting that best practices in radiation safety are rarely achieved in MA.
Abstract
Objective
Microcatheter angiography (MA) is often performed immediately following access of the common femoral artery using a 4 French micropuncture sheath directly attached to a 10 cubic centimeter (cc) syringe to evaluate the suitability of iliofemoral access. It can also be performed at the end of an operation to assess for access-related complications in procedures requiring large bore (≥12 French) percutaneous access. The operator's hands are particularly vulnerable in MA and we hypothesize that best practices in radiation safety are rarely achieved in MA.
Methods
A retrospective review was performed of all patients who underwent elective percutaneous endovascular aneurysm repair (pEVAR) at a single institution from 2020-2023. Operative reports and digital subtraction angiography (DSA) were reviewed to determine the prevalence of "pre-large bore" and "post-large bore" MA. The primary end-point was the rate of direct operator exposure in MA. Secondary end-points included the rate of intra-operative access complications and radiation dose area product (DAP).
Results
144 patients underwent pEVAR with 282 percutaneous femoral access sites. Of the 282 percutaneous common femoral artery access sites, 9% (N = 25) underwent pre-large bore MA only, 24% (N = 67) underwent post-large bore MA only, and 56% (N = 159) underwent both pre-large bore and post-large bore MA for a total of 410 microcatheter angiograms. The overall rate of direct operator exposure was 56% (N = 231/410) for MA. Individual rates of operator exposure ranged from 51-71% and the three most prevalent performers accumulated cumulative DAP values of 342, 386 and 479 Gy ∙cm2 from MA alone during the study period. Operator exposure was not associated with laterality, C-arm angulation, sheath size, or BMI. There were only 10 intra-operative or peri-operative access complications (6.9% overall; 3.5% per access site) of which only four were specifically recognized by MA.
Conclusion
MA was routinely performed in elective pEVAR and best practices in radiation safety were rarely achieved with a high rate of direct operator exposure to the beam of radiation. The overall rate of access-related complications in elective pEVAR is low and the window for detecting access-related complications with MA is narrow. Because of the high rate of operator exposure, selective MA and the development of guidelines for best practice technique MA should be considered.
Endovascular removal of intracardiac foreign bodies is currently perspective in interventional cardiology and demonstrates high efficiency with minimal invasiveness as evidenced by low percentage of intra- and postoperative complications, shorter hospital-stay and rapid rehabilitation.
M. Chernyavin, Ya.S. Samedov, K. Petrov et al.· Russian Journal of Cardiolog...· 0 citations
BACKGROUND
Retrograde tibial-pedal access is a well-established technique for managing peripheral arterial occlusive disease and its associated ischemic symptoms. While generally considered safe and effective, this method presents notable challenges due to the small caliber and, often, diseased nature of the target ves...
Ashwani Sastry, Sreejit Nair· Catheterization and cardiova...· 0 citations
The transradial approach (TRA) has become the preferred vascular access for coronary angiography and percutaneous coronary intervention (PCI), offering reductions in bleeding and vascular complications compared with the transfemoral approach, and lower mortality in patients with acute coronary syndromes (ACS). Technica...
Tanawat Attachaipanich, M. Khawaja, H. H. Virk et al.· Frontiers in Cardiovascular...· 0 citations
Background Postprocedural iliofemoral angiography is commonly used to detect access-site complications after transfemoral transcatheter aortic valve implantation (TF-TAVI). However, the clinical value of routine angiographic surveillance remains uncertain. Aims To compare vascular and access-site-related complications...
A. von Ehr, Jonathan Rilinger, Derek Y. Hazard et al.· JACC: Advances· 0 citations
Transcaval access was first described in animals in 2013 and in humans in 2014. It was initially developed for patients with peripheral artery disease who were undergoing transcatheter aortic valve replacement (TAVR), a procedure that requires large-bore access. Since then, transcaval access has been increasingly adopt...
M. Chiang, A. Ko, B. Chow et al.· Journal of Asian Pacific Soc...· 0 citations
PURPOSE
Repeated interventions for arteriovenous (AV) access dysfunction in hemodialysis patients are costly, burdensome, and detrimental to quality of life. The FLEX Vessel Preparation (VP) system utilizes a technique termed kinetic endovascular micro-incision creation (KEMIC) to improve vessel compliance and durabili...
R. Shahverdyan, Daniel G Clair, Jordan Knepper· Journal of Vascular Access· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.