Early national comparison of robotic versus conventional hip replacements for arthritis using National Joint Registry data: target trial emulation study
Sep 2026· British medical journal· Vol 394, pp. e100709· 2 citations· 30 references
Medicine
TL;DR
No significant differences were found in overall THR or patient survival, cause specific revision, or intraoperative complication risks between robotic and conventional groups, and Robotic THR was associated with a lower revision risk from causes related to implant malpositioning.
Abstract
Abstract Objectives To evaluate the early comparative effectiveness of robotic versus conventional total hip replacement (THR) in the UK. Design Target trial emulation study. Setting Public and private hospitals using data from the National Joint Registry of England, Wales, Northern Ireland, the Isle of Man, Guernsey, and Jersey. Participants 666 283 THRs performed between 2018 and 2024; 656 080 were conventional THRs and 10 203 were robotic THRs. Main outcome measures Five year THR implant survival (mean 2.5 year follow-up), all cause revision risk, cause specific revision risk, malpositioning revision risk, intraoperative complications, and patient survival up to five years. Kaplan-Meier survival analysis, Cox proportional hazards regression, and Fine and Gray models were used. Propensity score matching created comparable treatment groups to estimate the average treatment effect in the treated population. Results The five year implant survival of the matched conventional and robotic THR groups was 98.8% (95% confidence interval (CI) 98.6% to 99.0%) and 98.8% (CI 98.3% to 99.1%), respectively, with no difference in revision risk between groups (hazard ratio 0.96, 95% CI 0.75 to 1.22; P=0.73). Cause specific revision risk and intraoperative complication risks did not differ between groups. However, a significantly lower risk of revisions related to implant malposition (dislocation, leg length discrepancy, and malalignment) was observed in the robotic group (hazard ratio 0.53, 95% CI 0.30 to 0.93; P=0.03). The five year patient survival of the matched conventional and robotic THR groups was 96.3% (95% CI 95.8% to 96.8%) and 96.2% (95.2% to 97.0%), respectively, with no difference in all cause mortality risk (hazard ratio 1.12, 95% CI 0.95 to 1.34; P=0.17). Conclusions No significant differences were found in overall THR or patient survival, cause specific revision, or intraoperative complication risks between robotic and conventional groups. Robotic THR was associated with a lower revision risk from causes related to implant malpositioning. However, the possibility of unmeasured and residual confounding cannot be ruled out owing to the observational design. These results highlight the importance of careful evaluation of robotic technology in publicly funded healthcare systems because of the substantially higher capital and procedural costs.
Abstract Objective To evaluate the early comparative effectiveness of robotic versus conventional total knee replacement (TKR) and unicompartmental knee replacement (UKR) in the UK. Design Target trial emulation study. Setting Public and private hospitals using data from the National Joint Registry of England, Wales, N...
H. Mohammad, Andrew Judge, Xavier L. Griffin et al.· British medical journal· 2 citations
No difference in all-cause revision risk was observed between rTKA and cTKA groups, however, within the first 12 months, fewer revisions due to PJI occurred in the rTKA group.
Kasperi J. Alakylä, Emil Sylvestersson, M. Venäläinen et al.· Acta Orthopaedica· 0 citations
Background/Objectives: Robotic-assisted total hip arthroplasty (raTHA) improves the accuracy and reproducibility of acetabular component positioning compared with conventional THA (cTHA), but whether this translates into superior patient-reported outcomes and satisfaction remains debated. Methods: A retrospective compa...
D. González-Martín, A. Herrera-Rodríguez, J. M. Lomo-Garrote et al.· Journal of Clinical Medicine· 0 citations
To estimate the comparative effectiveness of single-stage versus two-stage revision for hip prosthetic joint infection (PJI) in Chinese tertiary hospitals by emulating the INFORM randomized trial using the target trial emulation framework. Retrospective cohort study emulating a target trial, reported per the TARGET gui...
Chang-Qing Zhang, Yu-Sheng Li, Chi Su et al.· Archives of Orthopaedic and...· 0 citations
In selected patients undergoing medial RA-UKA, no statistically significant age-group differences in measured early outcomes were detected during the first month, and serial observations provide reference points for early postoperative counselling but do not establish equivalent recovery or comparative safety.
Fei-Yu Mu, Zhen-Chao Huang, Wen-Zhe Wang et al.· BMC Musculoskeletal Disorder...· 0 citations
Aims
This study reports the interim outcomes of a randomized controlled trial comparing the accuracy of component positions, early functional outcomes, patient-reported outcome measures, and complications in conventional jig-based unicompartmental knee arthroplasty with navigational control (CO UKA) with robotic arm-as...
B. Kayani, A. Fontalis, J. Tahmassebi et al.· The Bone & Joint Journal· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.